Difference between revisions of "Nuclear Reports"

From Digital Transformation Wiki
Jump to navigation Jump to search
(Fix Link)
(Fix Link)
(No difference)

Revision as of 17:10, 7 August 2024

Search Reports

Strategic Focus Area

Nuclear

Product ID Reports
! Keyword 1
! Keyword 2
! Keyword 3
! Keyword 4
! Keyword 5
Strategic Focus Area
3002020870
| 3002020870
Cost Drivers and Recommended Practices for Sensor Deployment in Nuclear Power Facilities: Industry Survey and Feedback
| Sensor
| Cost
| Monitoring
| 
| 
Technology
| Technology
3002023752
| 3002023752
Digital Transformation Framework: Utility Strategy and Implementation Guide
| DX
| Strategy
| Guide
| 
| 
Strategy
| Strategy
3002018163
| 3002018163
Implementation, Deployment, and Continuing Improvement of Electronic Work Packages: Update to 3002005363
| eWP
| Mobile Work Management
| Digital Worker
| 
| 
Technology
| Technology
3002023904
| 3002023904
Program on Technology Innovation: Digital Twin Applications for Advanced Reactor
| Digital Twin
| Strategy
| Digital Engineering
| 
| 
Technology
| Technology
3002023765
| 3002023765
Electronic Work Package Platform Indicators and Pilot Project Findings
| eWP
| Mobile Work Management
| Digital Worker
| 
| 
Technology
| Technology
3002009128
| 3002009128
Use of LTE Cellular Network and Distributed Antenna Systems to Improve Connectivity and Increase Data Transfer: A Plant Monitoring Initiative
| DAS
| telecommunications
| Wireless
| Enabler
| 
Data
| Data
3002008206
| 3002008206
Cyber Security: Isolation for Maintenance, Monitoring, and Diagnostic Applications in Nuclear Power Facilities
| Cyber Security
| Isolation
| Segmentation
| Monitoring
| Sensor
Security
| Security
3002020428
| 3002020428
Digital Ports and Protocols Common to Operational Technology Systems: A Cyber Security Technical Assessment Methodology Topical Guide
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Security
| Security
3002023438
| 3002023438
Digital Systems Engineering: Digital I&C Lifecycle Strategy Guide
| Digital Controls
| I&C
| Strategy
| Digital Engineering
| 
Technology
| Technology
3002011816
| 3002011816
Digital Engineering Guide: Decision Making Using Systems Engineering
| Digital Engineering
| Guide
| 
| 
| 
Technology
| Technology
3002018391
| 3002018391
Digital Systems Engineering: Test Strategies and Methods
| Digital Engineering
| Strategy
| I&C
| 
| 
Technology
| Technology
3002023869
| 3002023869
Roadmap Towards an Autonomous Plant: A High-Level Overview of Technologies Important for Autonomous Plant Operation
| Automation
| Atonomous
| Digital
| 
| 
Technology
| Technology
3002018392
| 3002018392
HFAM - Human Factors Analysis Methodology for Digital Systems: A Risk-Informed Approach to Human Factors Engineering
| Digital 
| I&C
| Human Factors
| Engineering
| 
People & Process
| People & Process
3002022944
| 3002022944
Common Design Package for Guided Wave Sensors and Monitoring System: Real-Time NDE: Plant Modernization
| Monitoring
| Sensors
| Design
| 
| 
Technology
| Technology
3002002953
| 3002002953
Principles and Approaches for Developing Overall Instrumentation and Control Architectures that Support Acceptance in Multiple International Regulatory Environments
| Digital
| I&C
| Architecture
| 
| 
Technology
| Technology
3002000537
| 3002000537
Methods and Tools for Evaluating Digital Control System Architectures
| Architecture
| I&C
| Digital controls
| 
| 
Technology
| Technology
3002015754
| 3002015754
SymPLe Architecture and Methodology: Achieving Verifiable and High Integrity Instrumentation and Control Systems Through Complexity Awareness and Constrained Design
| Architecture
| Digital
| Digital Controls
| 
| 
Technology
| Technology
3002018393
| 3002018393
SymPLe Architecture Phase II: Platform Evolution
| Architecture
| Digital
| Digital Controls
| 
| 
Technology
| Technology
3002015757
| 3002015757
Guidelines for Electromagnetic Compatibility Testing of Power Plant Equipment: Revision 5 to TR-102323
| EMC
| EMI
| I&C
| Guide
| 
Data
| Data
3002025693
| 3002025693
Program on Technology Innovation: Landscape of Automation in Nuclear Power Plants
| Automation
| Atonomous
| Monitoring
| 
| 
Technology
| Technology
3002003126
| 3002003126
Advanced Nuclear Technology: Data-Centric Configuration Management for Efficiency and Cost Reduction: An Economic Basis for Implementation
| Configuration Management
| data-centric
| 
| 
| 
Technology
| Technology
1024859
| 1024859
Human Factors Engineering (HFE) Computer Based Training Module for Utilities Involved in Implementing Digital Instrumentation and Control Systems
| Digital Controls
| CBT
| Human Factors
| 
| 
People & Process
| People & Process
3002023837
| 3002023837
Program on Technology Innovation: Creating a Digital Twin of a Radiological Environment
| Digital Twin
| sensor
| monitoring
| 
| 
Technology
| Technology
3002020427
| 3002020427
Integrating the EPRI TAM into a Digital Control System Conceptual Design: A Cyber Security Technical Assessment Methodology Topical Guide
| Cyber Security
| Digital I&C
| Technical assesment methodology
| 
| 
Security
| Security
3002023839
| 3002023839
EPRI Robotics Research: Electromagnetic Compatibility Assessment of SPOT Robotic Platform
| robotics
| EMI
| EMC
| Digital
| 
Technology
| Technology
3002015755
| 3002015755
Digital Systems Engineering: Configuration Management Guideline
| digital
| I&C
| configuration management
| guide
| 
Technology
| Technology
3002015758
| 3002015758
Digital Systems Engineering: Requirements Engineering Guideline
| digital
| engineering
| I&C
| guide
| 
Technology
| Technology
3002020429
| 3002020429
Digital Engineering Guide: Documentation Strategies Topical Guide
| guide
| configuration
| strategy
| engineering
| 
Technology
| Technology
3002023800
| 3002023800
Energy Supply Common Information Model (ES-CIM) Testbed v1.0
| common information model
| integration
| interoperability
| testbed
| 
Data
| Data
3002020923
| 3002020923
Application Integration Using Standards-Based Messaging: Implementation of Energy Supply Common Information Model (ES-CIM) Interfaces
| common information model
| integration
| interoperability
| cloud
| 
Data
| Data
3002022172
| 3002022172
Energy Supply Common Information Model GitHub Repository (ES-CIM) v1.0
| common information model
| integration
| interoperability
| 
| 
Data
| Data
3002020920
| 3002020920
Plant Modernization Application Integration Study: Overview of Integration Cost and Challenges in Enterprise Projects
| common information model
| integration
| interoperability
| digital worker
| 
Data
| Data
3002020913
| 3002020913
Unmanned Aircraft System (UAS) User's Guide for Nuclear Power Plants: Implementation Guidance, Technologies and Applications, and Cost Savings Opportunities
| drone
| UAS
| inspections
| guide
| 
Technology
| Technology
3002018430
| 3002018430
Plant Modernization Toolbox
| modernization
| business case
| guide
| strategy
| 
Strategy
| Strategy
3002019454
| 3002019454
Business Case Analysis Model (BCAM) v2.0
| business case
| nuclear
| modernization
| 
| 
Strategy
| Strategy
3002015795
| 3002015795
Cyber Security Division of Responsibility Topical Guide
| cyber security
| digital
| guide
| 
| 
Security
| Security
3002015761
| 3002015761
Cyber Security Data Flow Identification and Documentation Topical Guide
| Cyber Security
| Technical Assessment Methodology
| data flow
| 
| 
Security
| Security
3002016346
| 3002016346
Application of Remote Monitoring Technologies to Risk-Inform Condition Based Radiological Surveys
| sensor
| monitoring
| radiation
| nuclear
| 
Technology
| Technology
3002015794
| 3002015794
Cyber Security Baseline Configuration Topical Guide
| Cyber Security
| Technical Assessment Methodology
| configuration management
| 
| 
Security
| Security
3002015759
| 3002015759
Domain Controller Cyber Security Data Sheet (CSDS) Topical Guide
| Cyber Security
| Technical Assessment Methodology
| configuration
| 
| 
Security
| Security
3002016698
| 3002016698
HAZCADS: Hazards and Consequences Analysis for Digital Systems - Revision 1
| digtial
| hazcads
| I&C
| assessment
| 
Security
| Security
3002018387
| 3002018387
DRAM: Digital Reliability Analysis Methodology
| digital
| analysis
| reliablity
| 
| 
Security
| Security
3002021063
| 3002021063
PRE-SW: Concrete Defect Detection Tool (CDDT) v1.0 Beta
| machine learning
| API
| image analysis
| inspection
| 
Technology
| Technology
3002023977
| 3002023977
NextGen RP - Specifications for Autonomous Contamination Survey Robots: Functional Specifications Document
| robotics
| automation
| radiation
| nuclear
| 
Technology
| Technology
3002020977
| 3002020977
Next Generation Radiation Protection (NextGen RP): Assessment of Remote and Automated Technologies to Optimize Nuclear Power Plant Emergency Preparedness Programs
| automation
| sensor
| monitoring
| radiation
| nuclear
Technology
| Technology
3002023860
| 3002023860
Artificial Intelligence for Inventory Management: Demand Prediction Proof-of-Concept Model Evaluation
| AI
| inventory
| prediction
| 
| 
Technology
| Technology
3002025138
| 3002025138
Preventive Maintenance Basis Database (PMBD) v7.0
| sensor
| monitoring
| fault tree
| strategy
| guide
People & Process
| People & Process
3002024847
| 3002024847
Longterm Asset Management Basis Design Application (LAMBDA) v1.05
| application
| lifecycle
| 
| 
| 
People & Process
| People & Process
3002020837
| 3002020837
Determining Configurability and Consequences of Error of Digital Devices
| digital
| 
| 
| 
| 
Technology
| Technology
3002022397
| 3002022397
Cable Fault Location Field Guide - Mobile App
| digital worker
| Mobile Work Management
| guide
| fault
| 
Technology
| Technology
3002018286
| 3002018286
Electric Motor Microelectromechanical Systems (MEMS): Sensors for the Detection of Internal Stressors
| sensors
| motor
| 
| 
| 
Technology
| Technology
3002018279
| 3002018279
Digital Equivalency Evaluation: Screening Checklist and Considerations, Revision 1-An Updated Approach That Considers Item Configurability and Consequences of Error
| digital
| engineering
|  guide
| 
| 
Technology
| Technology
3002018281
| 3002018281
Wireless Technologies as a Replacement for Degraded Cable Systems
| Cyber Security
| wireless
| telecommunications
| monitoring
| sensor
Data
| Data
3002012784
| 3002012784
Developing a Technical Basis for Using On-Line Equipment Condition Monitoring to Reduce Time-Based Preventive and Predictive Maintenance
| sensor
| monitoring
| guide
| reliability
| 
People & Process
| People & Process
3002023921
| 3002023921
Enhanced Security and Reliability Using Artificial Intelligence
| AI
| monitoring
| cyber security
| 
| 
Security
| Security
3002023839
| 3002023839
EPRI Robotics Research: Electromagnetic Compatibility Assessment of SPOT Robotic Platform
| robotics
| EMI
| EMC
| digital
| telecommunications
Technology
| Technology
3002021179
| 3002021179
Incident Response Scenario Development Methodology: A Methodology for Developing Incident Response Scenarios for Operational Technology
| OT
| cyber security
| 
| 
| 
Security
| Security
3002023751
| 3002023751
Exploration of Drone Indoor Navigation Using Visual Markers: An Evaluation of the Design and Testing of a Visual Navigation System
| drone
| UAV
| UAS
| 
| 
Technology
| Technology
3002023739
| 3002023739
Installing Patches and Updates Using a Bounded Specification: A Cyber Security Topical Guide
| Cyber Security
| software
| patch
| digital
| guide
Security
| Security
3002023747
| 3002023747
Cyber Security Exercise Scenarios: Second Edition
| Cyber Security
| 
| 
| 
| 
Security
| Security
3002023841
| 3002023841
SymPLe Architecture Phase II: Refinement, Advancement, and Demonstration of SymPLe Architecture
| architecture
| I&C
| nuclear
| 
| 
Technology
| Technology
3002023549
| 3002023549
Integrated Security Research Summary Infographic: Enhanced Security and Reliability Using Artificial Intelligence
| AI
| cyber security
| monitoring
| 
| 
Security
| Security
3002020430
| 3002020430
A Study in Analyzing Published Cyber Security Vulnerabilities Using Natural Language Processing
| Cyber Security
| AI
| NLP
| 
| 
Security
| Security
3002018370
| 3002018370
Instrumentation and Control (I&C) Connector Operating Experience and Maintenance Guide
| I&C
| guide
| OT
| 
| 
Technology
| Technology
3002018374
| 3002018374
Identifying Relationship Sets Topical Guide
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Data
| Data
3002018375
| 3002018375
Security Information and Event Monitor (SIEM) Configuration for Closed Networks Topical Guide
| Cyber Security
| Technical Assessment Methodology
| guide
| Monitoring
| 
Security
| Security
3002015795
| 3002015795
Cyber Security Division of Responsibility Topical Guide
| Cyber Security
| guide
| procurment
| 
| 
Security
| Security
3002011817
| 3002011817
Safety Integrity Level (SIL) Certification Efficacy for Nuclear Power
| OT
| I&C
| safety integrity level
| 
| 
Technology
| Technology
3002015793
| 3002015793
Secure Development, Integration, and Delivery (SDID) Audit Topical Guide
| Cyber Security
| procurment
| guide
| 
| 
Security
| Security
3002012707
| 3002012707
Wireless Technology Assessment: Analysis of Radiated Emissions from Common Phones, Laptops, and Tablets
| EMC
| wireless
| digital worker
| EMI
| RFI
Data
| Data
3002012754
| 3002012754
Cyber Security Program Guide for Nuclear Power Facilities
| Cyber Security
| guide
| nuclear
| 
| 
Security
| Security
3002011818
| 3002011818
Wireless Sensor Survey and General Specification
| EMI
| EMC
| monitoring
| sensor
| wireless
Data
| Data
3002010577
| 3002010577
Online Monitoring Guide for Equipment Diagnostics and Reliability-Nuclear Generation
| sensor
| monitoring
| guide
| 
| 
Technology
| Technology
3002008018
| 3002008018
Systems Engineering Process: Methods and Tools for Digital Instrumentation and Control Projects
| I&C
| guide
| 
| 
| 
People & Process
| People & Process
3002006737
| 3002006737
Design Considerations for Replacing Single Loop Controllers and Other Controls with Field Programmable Gate Array-Based Equipment
| I&C
| OT
| controllers
| FPGA
| 
Technology
| Technology
3002008025
| 3002008025
Guidance for Instrumentation and Control Equipment Reliability Management Based on China General Nuclear Power Company Experience
| I&C
| guide
| 
| 
| 
Technology
| Technology
3002005369
| 3002005369
Technologies for Enhancing Verifiability of Embedded I&C Systems in Nuclear Power: A Survey of Advanced FPGA and MEMs Technologies
| I&C
| MEMs
| FPGA
| 
| 
Technology
| Technology
3002004995
| 3002004995
Program on Technology Innovation: Analysis of Hazard Models for Cyber Security, Phase I
| Cyber Security
| hazard
| 
| 
| 
Security
| Security
3002005367
| 3002005367
Program on Technology Innovation: Video Content Analytics for Nuclear Process Monitoring: A Technology Survey
| machine vision
| AI
| monitoring
| sensor
| 
Technology
| Technology
3002005324
| 3002005324
Reverse Engineering via Computer Simulation and Visualization of Nuclear Plant Printed Circuit Boards
| digital
| OT
| 
| 
| 
Technology
| Technology
3002003255
| 3002003255
Cyber Security Procurement Methodology, Application Pilots: Lessons Learned
| Cyber Security
| procurment
| 
| 
| 
Security
| Security
3002023930
| 3002023930
Quick Insight Brief: Using Artificial Intelligence to Maximize the Benefits of Drones for Nuclear Power Plants
| AI
| drones
| inspections
| 
| 
Data
| Data
3002023718
| 3002023718
AI-Assisted Analysis of Ultrasonic Inspections
| AI
| inspection
| UT
| AI-assisted
| 
Technology
| Technology
3002023821
| 3002023821
Automating Corrective Action Programs in the Nuclear Industry
| AI
| machine learning
| NLP
| automation
| CAP
People & Process
| People & Process
3002021061
| 3002021061
Data Mining to Support Integrated Monitoring and Diagnostics
| APR
| monitoring
| data mining
| machine learning
| 
Data
| Data
3002021048
| 3002021048
Machine Learning to Improve ID Pit Sizing in Balance-of-Plant (BOP) Heat Exchanger Tubes: Target-Type 304 Stainless Steel Tubing
| machine learning
| eddy current inspection
| inspections
| 
| 
Technology
| Technology
3002020931
| 3002020931
Use of Augmented Intelligence for Decommissioning Planning
| AI
| augmented intelligence
| 
| 
| 
People & Process
| People & Process
3002021055
| 3002021055
Automated Analog Gauge Reader: Benchmarking and Python Source Code
| image processing
| AI
| machine vision
| monitoring
| 
Technology
| Technology
3002020411
| 3002020411
Proof of Concept: Developing a Machine Learning Algorithm Trained with Synthetic Data that Can Identify Parallel Misalignment in Real Vibration Data
| monitoring
| machine learning
| vibration
| AI
| 
Technology
| Technology
3002021067
| 3002021067
Quick Insight Brief: Leveraging Artificial Intelligence for the Nuclear Energy Sector
| machine learning
| AI
| guide
| 
| 
Technology
| Technology
3002021074
| 3002021074
Quick Insight Brief: Leveraging Artificial Intelligence for Nondestructive Evaluation
| AI
| machine learning
| NDE
| inspection
| 
Technology
| Technology
3002020120
| 3002020120
Application of Data Analytics to Mine Nuclear Plant Maintenance Data
| AI
| machine learning
| analytics
| data
| 
Technology
| Technology
3002019731
| 3002019731
Using Machine Learning to Predict Flow-Accelerated Corrosion Wear Rates
| machine learning
| FAC
| AI
| 
| 
Technology
| Technology
3002018272
| 3002018272
Technical Avatar Proof of Concept Using IBM Watson
| AI
| NLP
| machine learning
| 
| 
Technology
| Technology
3002015801
| 3002015801
Program on Technology Innovation: Leveraging Data Science for Electric Power Industry Transformation
| data
| analytics
| data science
| 
| 
People & Process
| People & Process
3002013197
| 3002013197
Guidance for Implementing a Data Validation and Reconciliation Program at Nuclear Power Plants
| data validation
| reconciliation
| monitoring
| sensor
| 
Technology
| Technology
3002005345
| 3002005345
Program on Technology Innovation: Evaluation of Data Reconciliation Methods for Power Recovery
| data validation
| reconciliation
| monitoring
| sensor
| 
Technology
| Technology
3002013226
| 3002013226
Image Processing of Four-Face Fuel Assembly Visual Inspections: A Feasibility Study
| machine vision
| inspection
| 
| 
| 
Technology
| Technology
3002023905
| 3002023905
Program on Technology Innovation: Using Digital Engineering Tools and Methods for New Nuclear Projects--A Review of the State of the Art
| digital twin
| digital engineering
| common information model
| 
| 
Technology
| Technology
3002023899
| 3002023899
Robotic Process Automation for Nuclear Power Plants: Evaluation of Near-Term Opportunities
| robotics
| automation
| drones
| automous
| 
Technology
| Technology
3002022555
| 3002022555
Quick Insight Brief: Elements of Digital Twins and Projects Updates
| digital twin
| 
| 
| 
| 
Technology
| Technology
3002020014
| 3002020014
Quick Insight Brief: Digital Twin Activities at EPRI
| digital twin
| 
| 
| 
| 
Technology
| Technology
3002012752
| 3002012752
Cyber Security Technical Assessment Methodology: Risk Informed Exploit Sequence Identification and Mitigation, Revision 1
| Cyber Security
| hazard
| methodology
| 
| 
Security
| Security
3002013296
| 3002013296
Human Factors Engineering (HFE) Computer Based Training Module for Utilities Involved in Implementing Digital Instrumentation and Control Systems
| CBT
| I&C
| Human Factors
| 
| 
People & Process
| People & Process
3002010493
| 3002010493
Advanced Nuclear Technology: Assessment of Automation Technologies to Reduce Chemistry and Radiochemistry O&M Costs
| Automation
| sensor
| chemistry
| 
| 
Technology
| Technology
3002010470
| 3002010470
Advanced Nuclear Technology: Guidance for Cyber Security During New Nuclear Plant Construction
| Cyber Security
| procurment
| nuclear
| 
| 
Security
| Security
3002010467
| 3002010467
Advanced Nuclear Technology: Augmented Reality Technologies for New Nuclear Plant Applications
| augmented reality
| AR
| digital worker
| nuclear
| 
Technology
| Technology
3002008039
| 3002008039
Program on Technology Innovation: HTTPN, Securing Nuclear Network Communications in the Age of the Internet of Things
| Cyber Security
| HTTPN
| nuclear
| 
| 
Data
| Data
3002004310
| 3002004310
Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification
| I&C
| human factors
| guide
| 
| 
People & Process
| People & Process
3002005236
| 3002005236
Advanced Nuclear Technology: Guideline for Online Monitoring Requirements to Support TSTF-425 Instrumentation and Control Surveillance Management Programs
| I&C
| monitoring
| guide
| sensor
| 
Technology
| Technology
3002002852
| 3002002852
Advanced Nuclear Technology: Guidance and Methodologies for Managing Digital Instrumentation and Control Obsolescence
| I&C
| obsolescence
| guide
| 
| 
Technology
| Technology
3002002499
| 3002002499
Cyber Security Procurement Methodology Training Module Rev. 14.00
| CBT
| cyber security
| procurment
| 
| 
Security
| Security
3002002556
| 3002002556
Guidelines for Instrument Calibration Extension/Reduction - Revision 2: Statistical Analysis of Instrument Calibration Data
| I&C
| sensor
| analysis
| 
| 
People & Process
| People & Process
3002019845
| 3002019845
Plant Modernization Business Case: Improved Thermal Performance Through Data Validation and Reconciliation: Cost-Benefit Analysis of DVR Analysis for Power Recovery or Measurement Uncertainty Recapture Uprates
| business case
| I&C
| sensor
| 
| 
Strategy
| Strategy
3002020579
| 3002020579
Plant Modernization Business Case: Digital Safety-Related Instrumentation and Control (I&C) System Modernizations: Cost-Benefit Analysis of Implementing Digital Upgrades to Analog Safety-Related I&C Components to Reduce Operating and Material Purchase Co
| business case
| I&C
| sensor
| 
| 
Strategy
| Strategy
3002020884
| 3002020884
Nuclear Plant Modernization Business Case: Business Process Automation for Online Work Management
| business case
| AI
| machine learning
| Automation
| digital worker
Strategy
| Strategy
3002019843
| 3002019843
Plant Modernization Business Case: Electronic Work Packages (eWPs) for Maintenance Work: Cost-Benefit Analysis of Implementing eWPs to Reduce Operating Costs
| business case
| eWP
| data anlaytics
| digital worker
| 
Strategy
| Strategy
3002019844
| 3002019844
Plant Modernization Business Case-Improved Thermal Performance Through Cycle Isolation Monitoring: Cost-Benefit Analysis of Cycle Isolation Monitoring for Addressing Valve Repairs That Lead to Lost MWe
| business case
| sensor
| 
| 
| 
Strategy
| Strategy
3002018424
| 3002018424
Plant Modernization Business Case: Monitoring and Diagnostic (M&D) Program Development: Cost-Benefit Analysis of Implementing Online Monitoring (OLM) and an M&D Program to Reduce Operating Costs and Avoid Outage and Derate Costs
| business case
| monitoring
| sensor
| M&D
| 
Strategy
| Strategy
3002020885
| 3002020885
Plant Modernization Business Case: Monitoring and Diagnostics (M&D) Program Development Update
| business case
| monitoring
| sensor
| M&D
| 
Strategy
| Strategy
3002018480
| 3002018480
Plant Modernization Business Case: Monitoring Piping Subjected to Flow-Accelerated Corrosion
| business case
| sensor
| FAC
| 
| 
Strategy
| Strategy
3002021027
| 3002021027
Plant Modernization Business Case: Drone Inspections of Containment Structures
| business case
| drones
| inspections
| AI
| machine vision
Strategy
| Strategy
3002021026
| 3002021026
Plant Modernization Business Case: Sensors for Post-Tensioned Tendons
| business case
| sensor
| 
| 
| 
Strategy
| Strategy
3002020581
| 3002020581
Plant Modernization Business Case: Cost-Benefit Analysis for Implementation of the EPRI Virtual NDE (VNDE) Ultrasonic Simulator
| business case
| simulator
| virtual
| 
| 
Strategy
| Strategy
3002018481
| 3002018481
Plant Modernization Business Case: Monitoring Heat Exchanger Shells
| business case
| sensor
| 
| 
| 
Strategy
| Strategy
3002018483
| 3002018483
Plant Modernization Business Case: Monitoring Service Water Piping
| business case
| sensor
| 
| 
| 
Strategy
| Strategy
3002020974
| 3002020974
NextGen RP Plant Modernization Business Case: Modernizing Nuclear Power Plant Emergency Response Field Monitoring Team Technologies
| business case
| drones
| sensor
| 
| 
Strategy
| Strategy
3002020440
| 3002020440
Plant Modernization Business Case: Automated Chemistry
| business case
| sensor
| chemistry
| automation
| 
Strategy
| Strategy
3002023760
| 3002023760
Investigation of Oil Sensor Technology for Online Monitoring, Rev. 1
| monitoring
| sensor
| oil
| 
| 
Technology
| Technology
3002023765
| 3002023765
Electronic Work Package Platform Indicators and Pilot Project Findings
| eWP
| digital worker
| mobile
| 
| 
Technology
| Technology
3002021295
| 3002021295
Enterprise Asset Management Guide: Implementation and Utilization
| enterprise asset mangement
| CMMS
| 
| 
| 
People & Process
| People & Process
3002018209
| 3002018209
Terry Turbine Virtual Reality Application (TTVR), Version 1.0
| virtual reality
| VR
| 3D
| 
| 
Technology
| Technology
3002018210
| 3002018210
Circuit Breaker Virtual Reality Application (CBVR) Version 1.0
| virtual reality
| VR
| 3D
| 
| 
Technology
| Technology
3002017753
| 3002017753
Developing a Cyber Security Culture in the Operational Technology (OT) Environment
| OT
| cyber security
| CBT
| training
| 
Security
| Security
3002012785
| 3002012785
Continuous Online Monitoring Pilot Study: Quick Guide Pilots Show Real Savings
| monitoring
| sensor
| M&D
| 
| 
Technology
| Technology
3002012917
| 3002012917
Mobile Rigger's Handbook (MRHB), v1.0
| digital worker
| mobile
| 
| 
| 
Technology
| Technology
3002012915
| 3002012915
Configuration and Demonstration of 433-MHz Wireless Gauge Reader
| machine vision
| wireless
| 
| 
| 
Data
| Data
3002011674
| 3002011674
Demonstration of Smart Monitoring and Diagnostic Technologies for Electrical Equipment: Electromagnetic Signature Analysis and Motor Current Signature Analysis
| monitoring
| sensor
| M&D
| 
| 
Technology
| Technology
3002011132
| 3002011132
Work Order Data Visualization Tool Tutorial Video
| data visualization
| 
| 
| 
| 
People & Process
| People & Process
3002009546
| 3002009546
Work Order Data Visualization Tool
| data visualization
| 
| 
| 
| 
People & Process
| People & Process
3002010622
| 3002010622
Program on Technology Innovation: Evaluation of 433 MHz Sensors in Nuclear Power Plants
| wireless
| sensors
| telecommunications
| 
| 
Data
| Data
3002005521
| 3002005521
Program on Technology Innovation: Machine Verification in Laser-Scanned Spaces - Status Update 2
| machine vision
| augmented reality
| AR
| 
| 
Technology
| Technology
3002003062
| 3002003062
Program on Technology Innovation: Machine Verification in Laser-Scanned Spaces-Status Update 1
| machine vision
| augmented reality
| AR
| 
| 
Technology
| Technology
3002020971
| 3002020971
Neutron Monitoring at Nuclear Power Plants
| sensor
| radiation
| monitoring
| 
| 
Technology
| Technology
3002018409
| 3002018409
Autonomous Indoor Radiation Survey and Inspection Drone Demonstration at Peach Bottom
| automation
| drones
| UAV
| UAS
| radiation
Technology
| Technology
3002013946
| 3002013946
Program on Technology Innovation: Heat Stress Monitoring and Sensors-Phase 1, State of Science of Wearable Physiological Monitors to Assess Occupational Heat Strain
| sensor
| monitoring
| digital worker
| 
| 
Technology
| Technology
3002005480
| 3002005480
Remote Monitoring Technology Guide for Radiation Protection: Field Implementation of Remote Monitoring, 2015 Revision
| robotics
| radiation
| monitoring
| 
| 
Technology
| Technology
3002023964
| 3002023964
SMART Chemistry Quick Guide - Data Trending/Evaluation/Transfer
| data trending
| data transfer
| guide
| chemistry
| guide
Technology
| Technology
3002023121
| 3002023121
SMART Chemistry Quick Guide-Online Boron Analysis Quick Guide
| monitoring
| chemistry
| automation
| guide
| sensor
Technology
| Technology
3002020976
| 3002020976
SMART Chemistry Quick Guide-BWR Online Offgas Analysis
| monitoring
| chemistry
| automation
| guide
| sensor
Technology
| Technology
3002020441
| 3002020441
SMART Chemistry: Plant Demonstrations
| monitoring
| chemistry
| automation
| guide
| sensor
Technology
| Technology
3002017886
| 3002017886
Chemistry Monitoring and Assessment Database Web Application (CMA Web), version 4.0
| monitoring
| chemistry
| guide
| sensor
| 
Technology
| Technology
3002015805
| 3002015805
SMART Chemistry QUICK GUIDE - Steam Generator Blowdown Online Monitoring: Modular Approach
| monitoring
| diagnostics
| sensor
| chemistry
| guide
Technology
| Technology
3002014377
| 3002014377
SMART Chemistry Quick Guide: Online Ion Chromatograph
| monitoring
| chemistry
| guide
| sensor
| 
Technology
| Technology
3002010493
| 3002010493
Advanced Nuclear Technology: Assessment of Automation Technologies to Reduce Chemistry and Radiochemistry O&M Costs
| Automation
| chemistry
| monitoring
| sensor
| 
Technology
| Technology
3002024148
| 3002024148
Remote Proctoring Implementation in the Nuclear Power Industry: A Review of Remote Proctoring for Knowledge Assessments
| AI
| training
| remote
| 
| 
People & Process
| People & Process
3002025291
| 3002025291
Assisted Analysis for Remote Visual Examination Data: Version 1.0 Pre-Beta Project Technical Update Report and Software Manual
| AI
| NDE
| 
| 
| 
Technology
| Technology
3002023709
| 3002023709
Ultrasonic Monitoring Technologies for Flow Accelerated Corrosion: Reference Guide
| NDE
| monitoring
| UT
| sensor
| 
Technology
| Technology
3002023703
| 3002023703
Assessment of 3D Camera Technology for Visual Testing
| 3D
| camera
| NDE
| 
| 
Technology
| Technology
3002023458
| 3002023458
Realtime Augmented Reality for Nondestructive Examination Report
| UT
| NDE
| AR
| augmented reality
| 
Technology
| Technology
3002023457
| 3002023457
Realtime Augmented Reality for Nondestructive Examination Video
| UT
| NDE
| AR
| augmented reality
| 
Technology
| Technology
3002021049
| 3002021049
Advanced Ultrasonic Technologies for Balance-of-Plant (BOP) Applications
| UT
| NDE
| sensor
| FAC
| 
Technology
| Technology
3002021019
| 3002021019
Feasibility of Monitoring Ultrasonic Examination Indications Using Phased Array Ultrasonics from a Fixed Position: Laboratory Testing of Crack Growth Experiments at Ambient Temperature
| UT
| NDE
| monitoring
| sensor
| 
Technology
| Technology
3002021043
| 3002021043
Automated Analysis of Ultrasonic Inspection of Reactor Vessel Upper Head Penetration Welds
| UT
| NDE
| automation
| sensor
| 
Technology
| Technology
3002021017
| 3002021017
Guided Wave Monitoring of Heat Exchanger Shells: Real-Time NDE-Plant Modernization
| guided wave
| monitoring
| sensor
| automation
| NDE
Technology
| Technology
3002018463
| 3002018463
Capability Study on Hyperspectral Imaging and Deep Neural Networks for Classification of Chemical Deposits: Feasibility of Classification of Reactor Vessel Deposits
| machine learning
| AI
| NDE
| inspection
| 
Technology
| Technology
3002013193
| 3002013193
Remote Visual Inspections with Unmanned Aerial Systems
| drone
| UAS
| UAV
| inspection
| 
Technology
| Technology
3002010448
| 3002010448
State of Structural Health Monitoring Technologies for Nuclear Applications
| UT
| guided wave
| monitoring
| 
| 
Technology
| Technology
3002010567
| 3002010567
Nondestructive Evaluation: Guided Wave Inspection Technology for Pipes with Elbows: Improvements to Inspection Reliability and Efficiency
| NDE
| inspection
| sensor
| monitoring
| 
Technology
| Technology
3002013152
| 3002013152
Nondestructive Evaluation: Virtual Mockups-Electronic Implantation of Flaw Responses into Previously Recorded Data
| NDE
| training
| virtual
| inspection
| 
Technology
| Technology
3002020914
| 3002020914
Quick Insight Brief: Digitized Knowledge Sharing-Curating Information form NRC Adams Using Text Mining and Natural Language Processing-A Proof of Concept
| NLP
| AI
| nuclear
| 
| 
Data
| Data
3002020872
| 3002020872
Continuous On-Line Monitoring (COLM): Water Intake Screen
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002020869
| 3002020869
Electrical Signature Analysis (ESA) for On-Line Equipment Condition Monitoring: Fault Detection Testing
| sesnors
| monitoring
| 
| 
| 
Technology
| Technology
3002020874
| 3002020874
Continuous On-Line Monitoring (COLM): Horizontal Motor, Low Voltage-Squirrel Cage
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002020873
| 3002020873
Continuous On-Line Monitoring (COLM): Vertical Pump, Deep Draft-Axial Flow
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002020875
| 3002020875
Continuous On-Line Monitoring (COLM): Horizontal Motor, Low Voltage-Wound Rotor
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015791
| 3002015791
Continuous On-Line Monitoring: HVAC - Air Handling Equipment - Air Handling Equipment - Propeller Fans
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015790
| 3002015790
Continuous On-Line Monitoring: HVAC - Air Handling Equipment - Vane Axial Fans
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015789
| 3002015789
Continuous On-Line Monitoring: HVAC - Air Handling Equipment - Centrifugal Fans
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015788
| 3002015788
Continuous On-Line Monitoring: Large Fan - Induced Draft or Forced Draft - Centrifugal
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015787
| 3002015787
Continuous On-Line Monitoring: Large Fan - Induced Draft or Forced Draft - Axial
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012767
| 3002012767
Continuous On-Line Monitoring: Main Condenser
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002016977
| 3002016977
Quick Guide: Continuous Online Monitoring (COLM)-Station MPT_GSU with De-Energized Tap Changer (DETC)
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012784
| 3002012784
Developing a Technical Basis for Using On-Line Equipment Condition Monitoring to Reduce Time-Based Preventive and Predictive Maintenance
| sensor
| monitoring
| 
| 
| 
Technology
| Technology
3002012781
| 3002012781
Continuous Online Monitoring (COLM): Vertical Motor, Medium Voltage <15KV - Solid Shaft - Rolling Element - Oil or Grease Lubricated
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012781
| 3002012781
Continuous Online Monitoring (COLM): Vertical Motor, Medium Voltage <15KV - Solid Shaft - Rolling Element - Oil or Grease Lubricated
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012780
| 3002012780
Continuous Online Monitoring (COLM): Horizontal Pump, Horizontal Pump - Multistage - Barrel Type
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012779
| 3002012779
Continuous Online Monitoring (COLM): Compressor, Rotary Screw - Oil Flooded and Oil Free
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012777
| 3002012777
Continuous Online Monitoring (COLM): Couplings, Elastomeric Type - Jaw or Spider Insert
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012776
| 3002012776
Continuous Online Monitoring (COLM): Couplings, Disc or Diaphragm Type
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012775
| 3002012775
Continuous Online Monitoring (COLM): Couplings, Gear Type - Grease Lubricated
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012774
| 3002012774
Continuous Online Monitoring (COLM): Heat Exchanger, General Tube Type
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012773
| 3002012773
Continuous Online Monitoring (COLM): Positive Displacement Pump
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012771
| 3002012771
Continuous Online Monitoring (COLM): Horizontal Motor, Medium Voltage <15kV - Horizontal - TEFC - Sleeve Bearing - Oil Lubed
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012770
| 3002012770
Continuous Online Monitoring (COLM): Horizontal Motor, Medium Voltage <15kV - Horizontal - TEFC - Rolling Element - Grease Lubed
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012769
| 3002012769
Continuous Online Monitoring (COLM): Horizontal Pumps, Horizontal - Single Stage - Single Suction
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012768
| 3002012768
Continuous Online Monitoring (COLM): Horizontal Pumps, Horizontal - Multistage - Split Case Pump
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002013864
| 3002013864
Continuous On-Line Monitoring (COLM): Horizontal Pumps, Horizontal - Single Stage - Double Suction
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002011820
| 3002011820
Online Monitoring - Engineering Change Package Content for a Distributed Antenna System and Wireless Vibration Sensors
| monitoring
| sensors
| telecommunications
| 
| 
Technology
| Technology
3002012766
| 3002012766
Continuous On-Line Monitoring (COLM): Horizontal Motors, Medium Voltage <15kV - Horizontal - Filters - Sleeve Bearing - Oil Lubed
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012765
| 3002012765
Continuous On-Line Monitoring (COLM): Medium Voltage Vertical Motors, Medium Voltage <15kV - Vertical - Solid Shaft - Tilt Pad - Sleeve Guide - Oil Lubed
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012763
| 3002012763
Continuous On-Line Monitoring (COLM): Vertical Pump, Vertical - Deep Draft - Radial Flow - Product Lube
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002000742
| 3002000742
On-Line Monitoring of Emergency Diesel Generators
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1022988
| 1022988
Guideline for On-Line Monitoring of Nuclear Power Plant Instrument Channel Performance
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1021187
| 1021187
Status Report on On-Line Monitoring: Generation Step-Up Transformers
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1021116
| 1021116
Guideline for Initiating an Online Monitoring Program for Nuclear Power Plants
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1016725
| 1016725
Requirements for On-line Monitoring in Nuclear Power Plants
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1015173
| 1015173
Plant Application of On-Line Monitoring for Calibration Interval Extension of Safety-Related Instruments
| sensors
| monitoring
| 
| 
| 
People & Process
| People & Process
1013486
| 1013486
Plant Application of On-Line Monitoring for Calibration Interval Extension of Safety-Related Instruments: Volume 1 and 2
| sensors
| monitoring
| 
| 
| 
People & Process
| People & Process
3002011818
| 3002011818
Wireless Sensor Survey and General Specification
| telecommunications
| sensors
| 
| 
| 
Data
| Data
3002010569
| 3002010569
Development of Prototype Modular Wireless Triaxial Vibration Sensor: Pilot Phase
| telecommunications
| sensors
| 
| 
| 
Data
| Data
3002008026
| 3002008026
Development of Prototype Modular Wireless Triaxial Vibration Sensor: Phase 2
| telecommunications
| sensors
| 
| 
| 
Data
| Data
3002000502
| 3002000502
Preventive Maintenance Practices for Digital Instrumentation and Control Systems
| I&C
| sensors
| controls
| 
| 
Technology
| Technology
3002018394
| 3002018394
Electromagnetic Interference (EMI) Troubleshooting Guide
| EMI
| guide
| EMC
| 
| 
Data
| Data
3002000528
| 3002000528
Guidelines for Electromagnetic Compatibility Testing of Power Plant Equipment: Revision 4 to TR-102323
| EMC
| EMI
| guide
| 
| 
Data
| Data
3002001823
| 3002001823
Cyber Security Procurement - Application of the Methodology, Second Example: Feedpump Turbine Speed Control
| Cyber Security
| control
| I&C
| 
| 
Security
| Security
3002002069
| 3002002069
Cyber Security Procurement-Application of the Methodology, Third Example: Digital Feedwater Control
| Cyber Security
| control
| I&C
| 
| 
Security
| Security
3002003255
| 3002003255
Cyber Security Procurement Methodology, Application Pilots: Lessons Learned
| Cyber Security
| 
| 
| 
| 
Security
| Security
3002020426
| 3002020426
Developing a Regulatory Requirements and Compliance Map: A Cyber Security Technical Assessment Methodology Topical Guide
| Cyber Security
| guide
| Technical assesment methodology
| 
| 
Security
| Security
3002017149
| 3002017149
SEL 487E Protective Relay Reference Cyber Security Data Sheet (CSDS): Cyber Security Technical Assessment Methodology Use Case Study
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Security
| Security
3002015737
| 3002015737
Exploit Sequence Identification and Mitigation (EXSIM) v1.0
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Security
| Security
3002015760
| 3002015760
Risk Informed Target Level Topical Guide
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Security
| Security
3002012753
| 3002012753
Cyber Security in the Supply Chain: Cyber Security Procurement Methodology, Revision 2
| Cyber Security
| procurment
| 
| 
| 
Security
| Security
3002012239
| 3002012239
Elemental Fault Signature Information for Select Power Plant Assets
| monitoring
| sensors
| 
| 
| 
Technology
| Technology
3002000755
| 3002000755
On-Line Monitoring Diagnostic Analysis for Emergency Diesel Generators
| COLM
| sensors
| monitoring
| 
| 
Technology
| Technology
3002000753
| 3002000753
On-Line Monitoring Diagnostic Analysis for Large Power Transformers
| COLM
| sensors
| monitoring
| 
| 
Technology
| Technology
3002015880
| 3002015880
Area-Wide Acoustic and Electromagnetic (AEM) Signature Health Monitoring: Phase 2
| monitoring
| sensors
| 
| 
| 
Technology
| Technology
3002023747
| 3002023747
Cyber Security Exercise Scenarios: Second Edition
| Cyber Security
| 
| 
| 
| 
Security
| Security
3002026347
| 3002026347
Torsional Vibration Monitoring of Deep Draft Vertical Pumps: Phase 2
| sensors
| monitoring
| vibration
| 
| 
Technology
| Technology
3002026348
| 3002026348
Guideline for System Monitoring by System Engineers
| monitoring
| systems
| 
| 
| 
People & Process
| People & Process
3002026403
| 3002026403
Ultrasonic Data Compression
| data
| ultrasonic
| 
| 
| 
Data
| Data
3002027454
| 3002027454
PRE-SW: EPRI 3D/AR Platform Application v2023 Beta
| AR
| augmented reality
| 
| 
| 
Technology
| Technology
3002028007
| 3002028007
Generating Synthetic Data with Deep Learning
| AI
| 
| 
| 
| 
Technology
| Technology
3002021024
| 3002021024
Radio Frequency Spectrum Management Guideline: Guidance for Wireless Coexistence Management in Nuclear Power Facilities
| communications
| management
| 
| 
| 
Data
| Data
3002022964
| 3002022964
Transformer and Switchyard Monitoring Technologies for Nuclear Power Plants-An Overview of Potential Applications
| monitoring
| sensors
| 
| 
| 
Technology
| Technology
3002023743
| 3002023743
Electromagnetic Compatibility Assessment Methodology (EMCAM): Revision 0
| EMI
| 
| 
| 
| 
Data
| Data
3002026368
| 3002026368
DSEUG Nuclear Plant Digital Project Experience 2023
| 
| 
| 
| 
| 
Technology
| Technology
3002026367
| 3002026367
Network Design Guide: Use Case-Based Approach for Operational Technology (OT) Networks
| network
| 
| 
| 
| 
Data
| Data
3002027821
| 3002027821
Continuous Online Monitoring Guidebook
| monitoring
| sensors
| 
| 
| 
Technology
| Technology
3002025348
| 3002025348
Li-Fi Wireless Communications: Technology Evaluation for Utility Applications
| communications
| 
| 
| 
| 
Technology
| Technology
3002026483
| 3002026483
Advanced Nuclear Technology: Lessons Learned and Best Practices from the Development of a Digital Twin for Construction Quality
| digital twin
| DT
| 
| 
| 
Technology
| Technology
3002018337
| 3002018337
Use of Data Validation and Reconciliation Methods for Measurement Uncertainty Recapture: Topical Report, Revision 0-A
| data
| DVR
| 
| 
| 
Technology
| Technology
3002026618
| 3002026618
The State of Sensors for Advanced Reactor Applications
| sensors
| 
| 
| 
| 
Technology
| Technology
3002025464
| 3002025464
Unmanned Ground System (UGS) User's Guide for Nuclear Power Plants: Implementation Guidance, Technologies and Applications, and Cost Savings Opportunities
| robotics
| 
| 
| 
| 
Technology
| Technology
3002023740
| 3002023740
Variable Frequency Drive with Motor Management Relay Cyber Security Data Sheet: A Cyber Security Technical Assessment Methodology Topical Guide
| cyb
| 
| 
| 
| 
Security
| Security
3002024294
| 3002024294
Concrete Defect Detection Tool (CDDT) v1.0
| AI
| machine vision
| 
| 
| 
Technology
| Technology
3002026347
| 3002026347
Torsional Vibration Monitoring of Deep Draft Vertical Pumps: Phase 2
| sensors
| monitoring
| vibration
| 
| 
Technology
| Technology
3002026348
| 3002026348
Guideline for System Monitoring by System Engineers
| monitoring
| systems
| 
| 
| 
People & Process
| People & Process
3002026403
| 3002026403
Data Compression Ultrasonic Data Compression
| data
| ultrasonic
| 
| 
| 
Data
| Data
3002027454
| 3002027454
EPRI 3D/AR Platform Application v2023 Beta PRE-SW: EPRI 3D/AR Platform Application v2023 Beta
| AR
| augmented reality
| 
| 
| 
Technology
| Technology
3002028007
| 3002028007
Synthetic Data with Deep Learning Generating Synthetic Data with Deep Learning
| AI
| 
| 
| 
| 
Technology
| Technology
3002021024
| 3002021024
Frequency Spectrum Management Guideline: Guidance for Wireless Coexistence Management in Nuclear Power Facilities Radio Frequency Spectrum Management Guideline: Guidance for Wireless Coexistence Management in Nuclear Power Facilities
| communications
| management
| 
| 
| 
Data
| Data
3002022964
| 3002022964
and Switchyard Monitoring Technologies for Nuclear Power Plants—An Overview of Potential Applications Transformer and Switchyard Monitoring Technologies for Nuclear Power Plants-An Overview of Potential Applications
| monitoring
| sensors
| 
| 
| 
Technology
| Technology
3002023743
| 3002023743
Compatibility Assessment Methodology (EMCAM): Revision 0 Electromagnetic Compatibility Assessment Methodology (EMCAM): Revision 0
| EMI
| 
| 
| 
| 
Data
| Data
3002026368
| 3002026368
Nuclear Plant Digital Project Experience 2023 DSEUG Nuclear Plant Digital Project Experience 2023
| 
| 
| 
| 
| 
Technology
| Technology
3002026367
| 3002026367
Design Guide: Use Case-Based Approach for Operational Technology (OT) Networks Network Design Guide: Use Case-Based Approach for Operational Technology (OT) Networks
| network
| 
| 
| 
| 
Data
| Data
3002027821
| 3002027821
Online Monitoring Guidebook Continuous Online Monitoring Guidebook
| monitoring
| sensors
| 
| 
| 
Technology
| Technology
3002025348
| 3002025348
Wireless Communications: Technology Evaluation for Utility Applications Li-Fi Wireless Communications: Technology Evaluation for Utility Applications
| communications
| 
| 
| 
| 
Technology
| Technology
3002026483
| 3002026483
Nuclear Technology: Lessons Learned and Best Practices from the Development of a Digital Twin for Construction Quality Advanced Nuclear Technology: Lessons Learned and Best Practices from the Development of a Digital Twin for Construction Quality
| digital twin
| DT
| 
| 
| 
Technology
| Technology
3002018337
| 3002018337
of Data Validation and Reconciliation Methods for Measurement Uncertainty Recapture: Topical Report, Revision 0-A Use of Data Validation and Reconciliation Methods for Measurement Uncertainty Recapture: Topical Report, Revision 0-A
| data
| DVR
| 
| 
| 
Technology
| Technology
3002026618
| 3002026618
State of Sensors for Advanced Reactor Applications The State of Sensors for Advanced Reactor Applications
| sensors
| 
| 
| 
| 
Technology
| Technology
3002025464
| 3002025464
Ground System (UGS) User’s Guide for Nuclear Power Plants: Implementation Guidance, Technologies and Applications, and Cost Savings Opportunities Unmanned Ground System (UGS) User's Guide for Nuclear Power Plants: Implementation Guidance, Technologies and Applications, and Cost Savings Opportunities
| robotics
| 
| 
| 
| 
Technology
| Technology
3002023740
| 3002023740
Frequency Drive with Motor Management Relay Cyber Security Data Sheet: A Cyber Security Technical Assessment Methodology Topical Guide Variable Frequency Drive with Motor Management Relay Cyber Security Data Sheet: A Cyber Security Technical Assessment Methodology Topical Guide
| cyb
| 
| 
| 
| 
Security
| Security
3002024294
| 3002024294
Defect Detection Tool (CDDT) v1.0 Concrete Defect Detection Tool (CDDT) v1.0
| AI
| machine vision
| 
| 
| 
Technology
| Technology
3002026528
| 3002026528
Assisted Analysis of Remote Visual Examination (AARVE) v0.1 Beta PRE-SW: Assisted Analysis of Remote Visual Examination (AARVE) v0.1 Beta
| Artificial Intelligence
| Automated analysis
|  Remote visual inspection
| 
| 
Technology
| Technology
3002029357
| 3002029357
Evaluation: Performance Demonstration Program Comparison to ASME Section XI, Appendix VIII and 10CFR50.55a--Year 2023 Nondestructive Evaluation: Performance Demonstration Program Comparison to ASME Section XI, Appendix VIII and 10CFR50.55a--Year 2023
| ASME Section XI, Appendix VIII
| In-service inspection (ISI)
| 10CFR50.55a
| Performance Demonstration (PD) Program
| 
Technology
| Technology
3002029142
| 3002029142
and Diagnostics Center Capabilities Survey: 2023 Results Monitoring and Diagnostics Center Capabilities Survey: 2023 Results
| Monitoring
| Diagnostics
| Advanced pattern recognition
| Capabilities
| Centralized
Strategy
| Strategy
3002028670
| 3002028670
Heat Exchanger and Condenser Tubing Eddy Current Inspection Best Practice Document Database (BOPECI) v1.0 Balance-of-Plant Heat Exchanger and Condenser Tubing Eddy Current Inspection Best Practice Document Database (BOPECI) v1.0
| Eddy Current Inspection
| Array Coil Inspection
| Bobbin Coil Inspection
| BOP Heat Exchanger and Condenser
|   Condenser Tubing Inspection Heat Exchanger Tubing Inspection
People & Process
| People & Process
3002028178
| 3002028178
Modernization Business Case – Monitoring and Diagnostic Program Development: Cost-Benefit Analysis of Implementing Online Monitoring (OLM) and a Monitoring and Diagnostic Program Using Advanced Pattern Recognition (APR) Software Plant Modernization Business Case - Monitoring and Diagnostic Program Development: Cost-Benefit Analysis of Implementing Online Monitoring (OLM) and a Monitoring and Diagnostic Program Using Advanced Pattern Recognition (APR) Software
| Critical components
|  Advanced pattern recognition (APR)
| Online monitoring (OLM)
| Preventative maintenance (PM)
| Plant modernization Monitoring diagnostics
Technology
| Technology
3002026577
| 3002026577
Distributed Ledger Technology: Examination of Nuclear Signatures and Material Control of Nuclear Fuel Using Distributed Ledger Technology Applications Nuclear Distributed Ledger Technology: Examination of Nuclear Signatures and Material Control of Nuclear Fuel Using Distributed Ledger Technology Applications
| Supply chain
| Nuclear fuel
| Tracking
| Distributed ledger technology
| Traceability Smart contract
Technology
| Technology
3002025309
| 3002025309
Interactive Database Knowledge Visualization Platform (IDKVP) v1.0 Beta PRE-SW: Interactive Database Knowledge Visualization Platform (IDKVP) v1.0 Beta
| PWR
| Inspection
| In-Service Inspection
| NDE
| Digital twin IDKVP Inspection Requirements Interactive Database ISI 3D Knowledge Visualization Platform
Data
| Data
3002029332
| 3002029332
Systematic Failures, Dependencies, and Common Cause Failures in Digital Systems: Leveraging EPRI’s Digital Engineering Framework for Probabilistic Risk Assessment (PRA) Modeling Untangling Systematic Failures, Dependencies, and Common Cause Failures in Digital Systems: Leveraging EPRI's Digital Engineering Framework for Probabilistic Risk Assessment (PRA) Modeling
| Digital Systems
| Probabilistic Risk Assessment
| Modeling
| Standards development
| Common cause failure Deterministic methods
Data
| Data
3002029091
| 3002029091
of EPRI Plant Modernization Strategy Development at Chubu: Showcasing the Value of Establishing a Plant Modernization Programs Application of EPRI Plant Modernization Strategy Development at Chubu: Showcasing the Value of Establishing a Plant Modernization Programs
| Continuous improvement
| Business case analysis
| Modernization process
| Modernization strategy
| Nuclear Plant Modernization Modernization Toolbox
Strategy
| Strategy