Difference between revisions of "Generation Reports"

From Digital Transformation Wiki
Jump to navigation Jump to search
(2024 Q4 Update)
Line 1,113: Line 1,113:
 
| Strategy
 
| Strategy
 
<pre style="display: none">| Strategy</pre>
 
<pre style="display: none">| Strategy</pre>
 +
 +
|-
 +
| 3002030671
 +
<pre style="display: none">| 3002030671</pre>
 +
| [https://www.epri.com/research/products/000000003002030671 Organizing and Using Data from Various Sources to Support Advanced Analytics and Artificial Intelligence in the Energy Sector: A Primer]
 +
<pre style="display: none">| Storage</pre>
 +
<pre style="display: none">| IEC 61850</pre>
 +
<pre style="display: none">| Common information model</pre>
 +
<pre style="display: none">| Data models</pre>
 +
<pre style="display: none">| Data science Data lineage</pre>
 +
| Strategy
 +
<pre style="display: none">| Strategy</pre>
 +
 +
|-
 +
| 3002028970
 +
<pre style="display: none">| 3002028970</pre>
 +
| [https://www.epri.com/research/products/000000003002028970 Generation Cyber Security Wiki v1.0]
 +
<pre style="display: none">| Cybersecurity</pre>
 +
<pre style="display: none">| Cyber</pre>
 +
<pre style="display: none">| Wiki</pre>
 +
<pre style="display: none">| Industrial Controls</pre>
 +
<pre style="display: none">| </pre>
 +
| Security
 +
<pre style="display: none">| Security</pre>
 +
 +
|-
 +
| 3002029854
 +
<pre style="display: none">| 3002029854</pre>
 +
| [https://www.epri.com/research/products/000000003002029854 Data Handling for Monitoring and Diagnostics Organizations]
 +
<pre style="display: none">| Monitoring</pre>
 +
<pre style="display: none">| Sensor</pre>
 +
<pre style="display: none">| Diagnostics</pre>
 +
<pre style="display: none">| Metadata</pre>
 +
<pre style="display: none">| Extract, Transform and Load (ETL)</pre>
 +
| Data
 +
<pre style="display: none">| Data</pre>
 +
 +
|-
 +
| 3002029821
 +
<pre style="display: none">| 3002029821</pre>
 +
| [https://www.epri.com/research/products/000000003002029821 Artificial Intelligence and Generative AI in the Energy Sector: Cyber Security Use-Cases, Considerations, and Implications]
 +
<pre style="display: none">| Cyber Security</pre>
 +
<pre style="display: none">| Cyber attack</pre>
 +
<pre style="display: none">| Artificial intelligence (AI)</pre>
 +
<pre style="display: none">| Cyber threats</pre>
 +
<pre style="display: none">| Generative AI</pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
 +
 +
|-
 +
| 3002029848
 +
<pre style="display: none">| 3002029848</pre>
 +
| [https://www.epri.com/research/products/000000003002029848 Monitoring and Diagnostics Center Capabilities Survey: 2024 Results]
 +
<pre style="display: none">| Monitoring</pre>
 +
<pre style="display: none">| Diagnostics</pre>
 +
<pre style="display: none">| Advanced pattern recognition</pre>
 +
<pre style="display: none">| Capabilities</pre>
 +
<pre style="display: none">| Centralized</pre>
 +
| Strategy
 +
<pre style="display: none">| Strategy</pre>
 +
 +
|-
 +
| 3002029902
 +
<pre style="display: none">| 3002029902</pre>
 +
| [https://www.epri.com/research/products/000000003002029902 Drone Inspection Applications for Hydroelectric Power Plants: Interactive Guide]
 +
<pre style="display: none">| Visual inspection</pre>
 +
<pre style="display: none">| Remote Inspection</pre>
 +
<pre style="display: none">| Drone</pre>
 +
<pre style="display: none">| Unmanned aircraft system (UAS)</pre>
 +
<pre style="display: none">| UAS/Drones Hydropower facilities</pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
 +
 +
|-
 +
| 3002031025
 +
<pre style="display: none">| 3002031025</pre>
 +
| [https://www.epri.com/research/products/000000003002031025 AI.EPRI Supplemental: AI for the Modern Energy Company]
 +
<pre style="display: none">| Artificial intelligence (AI)</pre>
 +
<pre style="display: none">| Generative AI</pre>
 +
<pre style="display: none">| </pre>
 +
<pre style="display: none">| </pre>
 +
<pre style="display: none">| </pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
 +
 +
|-
 +
| 3002028294
 +
<pre style="display: none">| 3002028294</pre>
 +
| [https://www.epri.com/research/products/000000003002028294 Lubrication Guide and Troubleshooting App (LGTA) v1.0]
 +
<pre style="display: none">| Predictive Maintenance</pre>
 +
<pre style="display: none">| Grease</pre>
 +
<pre style="display: none">| Oil</pre>
 +
<pre style="display: none">| Oil sampling</pre>
 +
<pre style="display: none">| Lubrication Best Practices Machinery Lubrication Oil Sample Oil Sample Analysis</pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
 +
 +
|-
 +
| 3002029852
 +
<pre style="display: none">| 3002029852</pre>
 +
| [https://www.epri.com/research/products/000000003002029852 Update 2024: Combustion Turbine Knowledge-Based Fault Signatures: Gas Turbine-Hot Section-Turbine-Bolted Rotor-Tilt Pad Bearing Only]
 +
<pre style="display: none">| Diagnostics</pre>
 +
<pre style="display: none">| Asset fault signatures</pre>
 +
<pre style="display: none">| Continuous online monitoring (COLM)</pre>
 +
<pre style="display: none">| </pre>
 +
<pre style="display: none">| </pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
 +
 +
|-
 +
| 3002030861
 +
<pre style="display: none">| 3002030861</pre>
 +
| [https://www.epri.com/research/products/000000003002030861 Digital Twin Auto Calibration Tool (DTACT) v1.3]
 +
<pre style="display: none">| Simulation</pre>
 +
<pre style="display: none">| Gas turbine</pre>
 +
<pre style="display: none">| Digital twin</pre>
 +
<pre style="display: none">| Auto Calibration</pre>
 +
<pre style="display: none">| </pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
 +
 +
|-
 +
| 3002029820
 +
<pre style="display: none">| 3002029820</pre>
 +
| [https://www.epri.com/research/products/000000003002029820 Cyber Risk Estimation Tool (CREST) v1.0]
 +
<pre style="display: none">| Risk Management</pre>
 +
<pre style="display: none">| Assessment</pre>
 +
<pre style="display: none">| Cyber Security</pre>
 +
<pre style="display: none">| Operational technology</pre>
 +
<pre style="display: none">| Risk Quantification</pre>
 +
| Security
 +
<pre style="display: none">| Security</pre>
 +
 +
|-
 +
| 3002029825
 +
<pre style="display: none">| 3002029825</pre>
 +
| [https://www.epri.com/research/products/000000003002029825 Cyber Threat Intelligence and the Development of Indicators of Compromise in OT]
 +
<pre style="display: none">| Detection</pre>
 +
<pre style="display: none">| Cyber Security</pre>
 +
<pre style="display: none">| Changing threat landscape</pre>
 +
<pre style="display: none">| Compromise</pre>
 +
<pre style="display: none">| Cyber threat intelligence</pre>
 +
| Security
 +
<pre style="display: none">| Security</pre>
 +
 +
|-
 +
| 3002029896
 +
<pre style="display: none">| 3002029896</pre>
 +
| [https://www.epri.com/research/products/000000003002029896 Remote Fault Detection in PV Plants Using Existing SCADA Instrumentation]
 +
<pre style="display: none">| Photovoltaic</pre>
 +
<pre style="display: none">| Solar</pre>
 +
<pre style="display: none">| Remote fault detection</pre>
 +
<pre style="display: none">| String fault</pre>
 +
<pre style="display: none">| Tracker fault</pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
 +
 +
|-
 +
| 3002029886
 +
<pre style="display: none">| 3002029886</pre>
 +
| [https://www.epri.com/research/products/000000003002029886 Advancements in Wind Turbine Performance Monitoring: Technology Development and Demonstration]
 +
<pre style="display: none">| Wind Turbine</pre>
 +
<pre style="display: none">| Performance monitoring</pre>
 +
<pre style="display: none">| Supervisory control and data acquisition (SCADA)</pre>
 +
<pre style="display: none">| Machine learning</pre>
 +
<pre style="display: none">| Yaw misalignment Pitch angle</pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
 +
 +
|-
 +
| 3002029828
 +
<pre style="display: none">| 3002029828</pre>
 +
| [https://www.epri.com/research/products/000000003002029828 Controls and Automation Guidebook: Condensed Versions of EPRI Generation Controls and Automation-Related Reports]
 +
<pre style="display: none">| Process Control</pre>
 +
<pre style="display: none">| Automation</pre>
 +
<pre style="display: none">| Advanced control</pre>
 +
<pre style="display: none">| Guidebook</pre>
 +
<pre style="display: none">| Controls</pre>
 +
| Technology
 +
<pre style="display: none">| Technology</pre>
  
 
|}
 
|}

Revision as of 10:19, 20 December 2024

Search Reports

Strategic Focus Area

Generation

Product ID Reports
! Keyword 1
! Keyword 2
! Keyword 3
! Keyword 4
! Keyword 5
Strategy Focus Area
3002025746
| 3002025746
A Primer on Data Analytics in Digital Transformation
| Data analytics
| Predictive analytics
| Digital platform
| Prescriptive analytics
| Data-driven decision making
Strategy
| Strategy
3002024586
| 3002024586
A Primer on the Role of Process Control and Automation in Digital Transformation: EPRI Digital Transformation Primer Series
| Process Control
| Automation
| Digital transformation
| Centralized control
|  
People & Process
| People & Process
3002024653
| 3002024653
Operationalization of Data for Analytics
| Operations
| Data Integration
| Analytics
| Data architecture
| Data models Digital transformation
Data
| Data
3002023316
| 3002023316
Hydropower Digital Twin Roadmap Development
| Monitoring
| Hydropower
| Diagnostics
| Roadmap
| Digital twin
Technology
| Technology
3002024417
| 3002024417
Digital Demonstration Facility: Digital Twin Update
| Gas turbine
| F-class gas turbines
| Digital twin (DT)
|  
|  
Technology
| Technology
3002024540
| 3002024540
Health Index for Balance of Plant Equipment: Phase I Progress Update
| Condition Based Maintenance
| Equipment Health
| Health index
| Data analytic tools
|  
Technology
| Technology
3002025266
| 3002025266
A Discussion on Automated Diagnostics
| Monitoring
| Automated diagnostics
| Data-driven fault signatures
| Knowledge-based fault signatures
|  
Technology
| Technology
3002024444
| 3002024444
Industrial Advanced Data Analytics Readiness Assessment Primer
| Optimization
| Automation
| Machine learning
| Artificial intelligence (AI)
| Advanced data analytics Data driven decision making
Data
| Data
3002023790
| 3002023790
Thermal Fatigue Model for Wind Turbine Generator Life Prediction: Physics-based Model for Real Time Health Monitoring
| Reliability
| Insulation systems
| Wind Turbine
| Generator
| Miner's rule Physics based thermal model
Technology
| Technology
3002023921
| 3002023921
Enhanced Security and Reliability Using Artificial Intelligence
| Security
| Cybersecurity
| Integrated security operations center (ISOC)
| Artificial intelligence (AI)
| Monitoring and diagnostic (M&D)
Security
| Security
3002024337
| 3002024337
Securing Wireless Communications in Power Generation Environments: A Process for Evaluating and Securing Wireless Deployments
| Wireless sensors
| Power generation
| Cyber Security
| Internet of Things (IoT)
| Industrial Internet of Things (IIoT) Operational technology (OT)
Data
| Data
3002013664
| 3002013664
I4Gen Intelligent Generation: Fundamentals of a Digital and Analytics Platform for Data Integration, Analysis, and Actionable Information
| Analytics
| System architecture
| Big Data
| Predictive analytics
| 14Gen Predictve maintenance
Technology
| Technology
3002011541
| 3002011541
Interactive Remote Access Guidance: Generation Cyber Security
| Cyber Security
| Cybersecurity
| Remote access
| Hardware-based cybersecurity
| Interactive remote access
Security
| Security
3002011542
| 3002011542
Connected Component Reference Architectures: Securing Connected Components in Power Generation-Interactive Remote Access, Vendor Use Case
| Information Technology
| Cyber Security
| Integration
| Enterprise Architecture
| Interactive remote access
Data
| Data
3002024348
| 3002024348
Controls Job Card Digitization Framework: Wireframe Layout Overview
| Flexible operations
| Digitization
| Thermal power systems
|  
|  
Technology
| Technology
3002024507
| 3002024507
New Applications of Remote Sensing Technologies in Aquatic Habitat Assessments: Summary of Findings
| Remote Sensing
| Drones
| sonar
| Artificial intelligence (AI)
|  
Technology
| Technology
3002024049
| 3002024049
Drone Applications for LP Steam Turbines: Interactive Guide
| Steam turbine
| Visual inspection
| Remote Inspection
| Drone
| UAS Last Stage Blade
Technology
| Technology
3002024159
| 3002024159
A Critical Assessment of Boiler Chemistry Action Level Limits Using Electrochemical Techniques and Computerized Tomography
| Boiler water chemistry
| X-ray computed tomography
| All-volatile treatment
| Chloride contamination
| Localized corrosion rates Oxide layer growth
Technology
| Technology
3002024097
| 3002024097
Generator Rotor Ground Faults-Online Detection
| Online Monitoring
| Generator rotor
| Ground faults
| Generator rotor damage
|  
Technology
| Technology
3002024723
| 3002024723
Work Management Guidelines for Power Plant Personnel: Long-Range Plans, Outages, Preventive Maintenance, Core Maintenance Schedules, and Daily Schedule Interactions Explained
| Scheduling
| Outage
| Work planning
| On-line maintenance
| Work management
People & Process
| People & Process
3002024227
| 3002024227
High-Level Flexibility Assessment and Benchmarking Tool: Combined-Cycle Units
| Combined Cycle
| Operational flexibility
| Benchmarking
| Assessments
|  
Technology
| Technology
3002024325
| 3002024325
Application of In-Situ Optical Continuous Emission Monitoring Systems under Current Regulatory Framework: Gas Turbine Combined Cycle Case Study
| UV-DOAS
| Gas turbine combined cycle (GTCC)
| Continuous emissions monitoring (CEM)
| Laser based monitors
| Multi-specie monitors
Technology
| Technology
3002016451
| 3002016451
Wind Turbine Performance Monitoring Methods Development and Demonstration: Digitalization of Wind Assets to Increase Production Revenue
| Operations and Maintenance (O&M)
| Digitalization
| Power curves
| Wind Turbine Performance Monitoring
|  
Technology
| Technology
3002016434
| 3002016434
Wind Turbine Gearbox Reliability, Damage Prediction, and Recommendations for Life Improvement: Digitalization of Wind Assets to Reduce O&M Costs
| Bearings
| Gears
| Health monitoring
| Gearbox
| Digitalization Drivetrain
Technology
| Technology
3002022015
| 3002022015
Summary of Insight Through the Integration of Information for Intelligent Generation (I4Gen): 2021 Update
| Sensors
| Data analytics
| Digital transformation
| Return on investment
|  
Data
| Data
3002022113
| 3002022113
Introduction to Data Integration for Power Generation
| Data Integration
| Data architecture
| Data platform
|  
|  
Data
| Data
3002022197
| 3002022197
Digital Twin Self Calibration Tool: Guideline for Gas Turbines v1.0
| Gas turbine
| Digital twin
| Historian data
| Model calibration
| Multi-unit calibration
Technology
| Technology
1017638
| 1017638
Best Practices for the Application of Hand-Held Computers to Operator Rounds
| Operator rounds
| Electronic data collection
| Handheld computers
|  
|  
People & Process
| People & Process
3002020549
| 3002020549
Digital Twin: A Primer on Digital Twins with a Focus on Gas Turbines
| Gas Turbines
| Digital twin
| Artificial intelligence (AI)
| Machine learning (ML)
| Computer-based modeling
Technology
| Technology
3002018048
| 3002018048
I4Gen Intelligent Generation: Digital Platform Roadmap
| Data analytics
| System architecture
| Predictive analytics
| Digital transformation
| Digital platform
Strategy
| Strategy
3002020702
| 3002020702
Advanced Thermal Performance Monitoring Methods
| Performance Evaluation
| Heat Rate
| Thermal Efficiency
| Diagnostic models
| Thermal performance monitoring Heat balance models
Technology
| Technology
3002014276
| 3002014276
Mobile Deployment Technology for Fossil Stations: Member Case Studies, 2018
| Cost-benefit analysis
| Financial modeling
| Mobile work management
| Return on investment (ROI)
|  
Technology
| Technology
3002023752
| 3002023752
Digital Transformation Framework: Utility Strategy and Implementation Guide
| Innovation
| Modernization
| Digital transformation
| Strategy framework
|  
Strategy
| Strategy
3002011560
| 3002011560
EPRI I4Gen Evaluation of Predictive Analytics Techniques
| Predictive Maintenance
| Neural Networks
| Artificial Intelligence
| Predictive analytics
| I4Gen Machine learning
Data
| Data
3002013663
| 3002013663
I4GEN Intelligent Generation White Paper: Maturity Levels for Key Application Areas Within EPRI's Intelligent Plant Concept
| Automation
| Digital Systems
| Data analytics
| Process controls
| Advanced monitoring Intelligent generation
Strategy
| Strategy
3002015109
| 3002015109
I4Gen Project 1: Data Visualization: EPRI v16.0
| Data visualization
| Dashboard
| Data-driven decisions
| Team collaboration
|  
Data
| Data
3002018040
| 3002018040
Remaining Useful Life Approaches for Rotating Equipment Case Study and Implementation Evaluation
| Rotating Machinery
| Condition-Based Maintenance
| Prognostics and Health Management
| Remaining useful life
|  
Technology
| Technology
3002019837
| 3002019837
Equipment Health Dashboard Optimization
| Reliability
| Data visualization
| Equipment health dashboard
|  
|  
Data
| Data
3002016871
| 3002016871
Digital Worker and Data Collection: A Proof of Concept
| Sensors
| Data Compilation
| Worker Safety
| Power generation
| Digital technology Digital worker
Technology
| Technology
3002023360
| 3002023360
Securing Digital Worker Technologies: Operational Technology(OT)/Information Technology (IT) Framework for Evaluating Cyber Security when Deploying Digital Worker Technology
| Information Technology
| Cyber Security
| Information technology/operations technology (IT/OT) convergence
| Operational technology (OT)
| Digital worker technology IT/OT integration
Security
| Security
3002020296
| 3002020296
Tag Whisperer (TW) v1.0
| Standardization
| AI
| NLP
|  
|  
Data
| Data
3002021062
| 3002021062
Application of Novel Random Forest Approach for Environmental Controls: Development Status
| Electrostatic Precipitators
| Emission Control
| Random forest
| Machine learning
| Artificial intelligence (AI)
Data
| Data
3002020233
| 3002020233
Improving Large-Scale PV Plant Monitoring and Diagnostics: Irradiance Sensor Benefit-Cost Analysis and Accuracy Assessment
| Performance
| Monitoring and diagnostics
| Sensor
| Photovoltaic
| Irradiance Pyranometer
Technology
| Technology
3002021732
| 3002021732
Evaluating Photovoltaic (PV) Plant Health: Best Practices for Comparing Actual Performance Versus Expected
| Performance
| Photovoltaics
| Solar
| Health
| Regression Empirical
Technology
| Technology
3002025605
| 3002025605
Wind Network for Enhanced Reliability (WinNER) v2.0
| Reliability
| Bearings
| Gears
| Wind Turbine
| Rotor Blade
Data
| Data
3002023104
| 3002023104
ReFLEx Calculator: Impact of Site and Operating Conditions on Wind Turbine Life Infographic
| Wind Turbines
| Budgeting
| O&M
| Components
| Operating conditions Life expectancy
Technology
| Technology
3002022663
| 3002022663
I4GEN(r) Insight Through the Integration of Information for Intelligent Generation
| Monitoring and diagnostics
| Digital technology
| Success story
| Generating assets
| Intelligent generation Plant modernization
Strategy
| Strategy
3002003913
| 3002003913
Predictive Maintenance Technologies: An Overview of Motor Current Signature Analysis and Electromagnetic Signature Analysis Enterprise Asset Management Guide: Implementation and Utilization
| Anomaly detection
| Predictive maintenance
| Electromagnetic signature analysis (EMSA)
| Motor currant signature analyis (MCSA)
|  
Technology
| Technology
3002015411
| 3002015411
Remaining Useful Life Approaches for Rotating Equipment
| Rotating Machinery
| Condition-Based Maintenance
| Prognostics and Health Management
| Remaining useful life
|  
Technology
| Technology
3002016342
| 3002016342
Nondestructive Evaluation (NDE) Mapping Technology Research for Feedwater Heater Shell Flow-Accelerated Corrosion (FAC)
| Nondestructive evaluation (NDE)
| Flow-accelerated corrosion (FAC)
| Ultrasonic testing (UT)
| Feedwater chemistry
| Feedwater heater (FWH) shell Pulse eddy current (PEC)
Technology
| Technology
3002011933
| 3002011933
Use of Asset Fault Signatures in Conjunction with Advanced Pattern Recognition Software
| Advanced pattern recognition
| APR
| AFS
| Asset fault signatures
| Fault diagnostics
Technology
| Technology
3002021295
| 3002021295
Enterprise Asset Management Guide: Implementation and Utilization
| Asset management
| Work management
| Computerized maintenance management system (CMMS)
| Enterprise asset management (EAM)
|  
People & Process
| People & Process
3002006661
| 3002006661
Integrating Bulk Power Generation Assets into the Common Information Model
| Semantic model
| Unified Modeling Language (UML)
| Common information model (CIM)
| Data Model
| Generation standards
Data
| Data
3002011218
| 3002011218
Guide to Develop Asset Fault Signature Using Fleetwide Prognostic and Health Management Suite Software
| Plant Health Monitoring Users Group
| Asset fault signature (AFS)
| Diagnostic advisor (DA)
|  
|  
Technology
| Technology
3002015404
| 3002015404
Maintenance Case Study: Equipment Reliability Data Platform Specification-Proposed Connection of Korea Western Power Co.'s Maintenance Management System to EPRI Applications
| Preventive Maintenance
| Equipment Reliability
| Data analytics
|  
|  
Technology
| Technology
3002024219
| 3002024219
Evaluation of Closure Effects on Groundwater Quality: Initial Data Summary and Description of Machine Learning and Advanced Statistics Used in the Analysis
| Machine Learning
| AI
| Analysis
| 
| 
Technology
| Technology
3002027417
| 3002027417
Understanding Software Bill of Materials for Cyber Security
| cyber security
| procurment
| 
| 
| 
Security
| Security
3002027428
| 3002027428
Cyber Security Risk Assessment: A Case Study in Digital Overspeed Protection Systems
| cyber security
| 
| 
| 
| 
Security
| Security
3002027429
| 3002027429
Cyber Security Procurement Topical Guide: For Control System and Operational Technology Installation and Upgrade in Power Generation Facilities
| cyber security
| 
| 
| 
| 
Security
| Security
3002027732
| 3002027732
OT Cyber Security Disaster Recovery Plan Guide
| cyber security
| 
| 
| 
| 
Security
| Security
3002027485
| 3002027485
Sensor Rationale Quick Reference Sheet
| sensors
| 
| 
| 
| 
Technology
| Technology
3002027426
| 3002027426
Identity and Access Management Guideline: Generation Cyber Security
| cyber security
| 
| 
| 
| 
Security
| Security
3002028319
| 3002028319
Equipment Health Dashboard Development Insights
| visualization
| 
| 
| 
| 
Data
| Data
3002027488
| 3002027488
Data Governance for the Power Industry
| governance
| data
| 
| 
| 
Data
| Data
3002027489
| 3002027489
Interim Report: Combustion Turbine Knowledge-Based Fault Signatures
| signatures
| 
| 
| 
| 
Data
| Data
3002027476
| 3002027476
Controls and Automation Guidebook: Condensed Versions of EPRI Generation Controls and Automation Related Reports
| automation
| 
| 
| 
| 
Data
| Data
3002028149
| 3002028149
Developing and Maintaining Asset Hierarchy and Master Equipment Lists of Power Plants: Power Plant Asset Hierarchies, Naming Conventions and Classifications
| data
| 
| 
| 
| 
Data
| Data
3002027431
| 3002027431
Remote Access Jump Host Hardening Field Guide
| cyber security
| 
| 
| 
| 
Security
| Security
3002027895
| 3002027895
Adaptive Predictive Expert Control Optimizer
| automation
| 
| 
| 
| 
Technology
| Technology
3002026663
| 3002026663
Machine Learning Techniques for Wind Turbine Performance Assessments: Wind Wake and Yaw Misalignment Identification, Quantification and Rectification
| Machine Learning
| ML
| AI
| 
| 
Technology
| Technology
3002028171
| 3002028171
Control Guides (CGA) v1.0
| Optimization
| Control
| Training
| Tuning
| 
Technology
| Technology
3002029143
| 3002029143
Enabling Automated Diagnostics Using Knowledge-Based Fault Signatures: Enabling Automated Diagnostics
| Power generation
| Supplemental project
| Digital transformation
| Automated diagnostics
| Knowledge-based fault signatures Reduced costs
Technology
| Technology
3002029720
| 3002029720
Security Design Architecture Review: Solar Inverters
| System Reliability
|  Security
| Risk
|  Supplemental project
| Solar inverter Inverter-based renewables
Security
| Security
3002028707
| 3002028707
Renewables Communications: Use Cases, Communications Technologies, and Implementation Considerations
| Communications
| Wind
| Solar
| Renewables
| Renewable Generation
Technology
| Technology
3002028031
| 3002028031
Risk Based Asset Management (RBAM) v1.0
| PM
| Asset management
| Risk
| PdM
| RACI
People & Process
| People & Process
3002023913
| 3002023913
Evaluation of Satellite Weather Data and Machine Learning Models for PV Performance Monitoring
| Monitoring
| Weather
|  Sensor
| Photovoltaic
| Machine learning Satellite
Data
| Data
3002027983
| 3002027983
Duke Energy and EPRI Develop Wind Turbine Reliability Methods for Forecasting Operation and Maintenance Budget
| Reliability
| Forecasting
| Wind Turbines
| Operations and Maintenance (O&M)
| 
People & Process
| People & Process
3002027981
| 3002027981
Duke Energy Optimizes Cyber Security for Generation Fleet
| Cyber Security
| Operational technology (OT)
| Generation fleet
| Risk‐informed methodology
| 
Security
| Security
3002028807
| 3002028807
Asset Management Digitalization: Guidelines for Enabling Power Plant Asset Lifecycle Information Management Leading Practice
| Digital twin
| Enterprise asset management (EAM)
| Asset configuration management
| Asset management digitalization
| Information exchange/interoperability Plant Asset Information Management
People & Process
| People & Process
3002028717
| 3002028717
Sensor Failure Detection
| Automation
| Metadata
| Data science
| Machine learning
| Neural network Sensor failure
Technology
| Technology
3002029803
| 3002029803
Developing and Maintaining Asset Hierarchy and Master Equipment Lists of Power Plants: Power Plant Asset Hierarchies, Naming Conventions, and Classifications
| Classification
| Asset hierarchy
| Equipment database
| Asset digitalization
| Master equipment list (MEL) Master Equipment Type Library (METL)
Strategy
| Strategy
3002030671
| 3002030671
Organizing and Using Data from Various Sources to Support Advanced Analytics and Artificial Intelligence in the Energy Sector: A Primer
| Storage
| IEC 61850
| Common information model
| Data models
| Data science Data lineage
Strategy
| Strategy
3002028970
| 3002028970
Generation Cyber Security Wiki v1.0
| Cybersecurity
| Cyber
| Wiki
| Industrial Controls
| 
Security
| Security
3002029854
| 3002029854
Data Handling for Monitoring and Diagnostics Organizations
| Monitoring
| Sensor
| Diagnostics
| Metadata
| Extract, Transform and Load (ETL)
Data
| Data
3002029821
| 3002029821
Artificial Intelligence and Generative AI in the Energy Sector: Cyber Security Use-Cases, Considerations, and Implications
| Cyber Security
| Cyber attack
| Artificial intelligence (AI)
| Cyber threats
| Generative AI
Technology
| Technology
3002029848
| 3002029848
Monitoring and Diagnostics Center Capabilities Survey: 2024 Results
| Monitoring
| Diagnostics
| Advanced pattern recognition
| Capabilities
| Centralized
Strategy
| Strategy
3002029902
| 3002029902
Drone Inspection Applications for Hydroelectric Power Plants: Interactive Guide
| Visual inspection
| Remote Inspection
| Drone
| Unmanned aircraft system (UAS)
| UAS/Drones Hydropower facilities
Technology
| Technology
3002031025
| 3002031025
AI.EPRI Supplemental: AI for the Modern Energy Company
| Artificial intelligence (AI)
| Generative AI
| 
| 
| 
Technology
| Technology
3002028294
| 3002028294
Lubrication Guide and Troubleshooting App (LGTA) v1.0
| Predictive Maintenance
| Grease
| Oil
| Oil sampling
| Lubrication Best Practices Machinery Lubrication Oil Sample Oil Sample Analysis
Technology
| Technology
3002029852
| 3002029852
Update 2024: Combustion Turbine Knowledge-Based Fault Signatures: Gas Turbine-Hot Section-Turbine-Bolted Rotor-Tilt Pad Bearing Only
| Diagnostics
| Asset fault signatures
| Continuous online monitoring (COLM)
| 
| 
Technology
| Technology
3002030861
| 3002030861
Digital Twin Auto Calibration Tool (DTACT) v1.3
| Simulation
| Gas turbine
| Digital twin
| Auto Calibration
| 
Technology
| Technology
3002029820
| 3002029820
Cyber Risk Estimation Tool (CREST) v1.0
| Risk Management
| Assessment
| Cyber Security
| Operational technology
| Risk Quantification
Security
| Security
3002029825
| 3002029825
Cyber Threat Intelligence and the Development of Indicators of Compromise in OT
| Detection
| Cyber Security
| Changing threat landscape
| Compromise
| Cyber threat intelligence
Security
| Security
3002029896
| 3002029896
Remote Fault Detection in PV Plants Using Existing SCADA Instrumentation
| Photovoltaic
| Solar
| Remote fault detection
| String fault
| Tracker fault
Technology
| Technology
3002029886
| 3002029886
Advancements in Wind Turbine Performance Monitoring: Technology Development and Demonstration
| Wind Turbine
| Performance monitoring
| Supervisory control and data acquisition (SCADA)
| Machine learning
| Yaw misalignment Pitch angle
Technology
| Technology
3002029828
| 3002029828
Controls and Automation Guidebook: Condensed Versions of EPRI Generation Controls and Automation-Related Reports
| Process Control
| Automation
| Advanced control
| Guidebook
| Controls
Technology
| Technology