Catalog

From Digital Transformation Wiki
Revision as of 17:48, 9 August 2023 by User (talk | contribs) (1 revision imported)
Jump to navigation Jump to search

Search Reports

Strategic Focus Area

Nuclear

Product ID Reports
! Keyword 1
! Keyword 2
! Keyword 3
! Keyword 4
! Keyword 5
Strategic Focus Area
3002020870
| 3002020870
Cost Drivers and Recommended Practices for Sensor Deployment in Nuclear Power Facilities: Industry Survey and Feedback
| Sensor
| Cost
| Monitoring
| 
| 
Technology
| Technology
3002023752
| 3002023752
Digital Transformation Framework: Utility Strategy and Implementation Guide
| DX
| Strategy
| Guide
| 
| 
Strategy
| Strategy
3002018163
| 3002018163
Implementation, Deployment, and Continuing Improvement of Electronic Work Packages: Update to 3002005363
| eWP
| Mobile Work Management
| Digital Worker
| 
| 
Technology
| Technology
3002023904
| 3002023904
Program on Technology Innovation: Digital Twin Applications for Advanced Reactor
| Digital Twin
| Strategy
| Digital Engineering
| 
| 
Technology
| Technology
3002023765
| 3002023765
Electronic Work Package Platform Indicators and Pilot Project Findings
| eWP
| Mobile Work Management
| Digital Worker
| 
| 
Technology
| Technology
3002009128
| 3002009128
Use of LTE Cellular Network and Distributed Antenna Systems to Improve Connectivity and Increase Data Transfer: A Plant Monitoring Initiative
| DAS
| telecommunications
| Wireless
| Enabler
| 
Data
| Data
3002008206
| 3002008206
Cyber Security: Isolation for Maintenance, Monitoring, and Diagnostic Applications in Nuclear Power Facilities
| Cyber Security
| Isolation
| Segmentation
| Monitoring
| Sensor
Security
| Security
3002020428
| 3002020428
Digital Ports and Protocols Common to Operational Technology Systems: A Cyber Security Technical Assessment Methodology Topical Guide
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Security
| Security
3002023438
| 3002023438
Digital Systems Engineering: Digital I&C Lifecycle Strategy Guide
| Digital Controls
| I&C
| Strategy
| Digital Engineering
| 
Technology
| Technology
3002011816
| 3002011816
Digital Engineering Guide: Decision Making Using Systems Engineering
| Digital Engineering
| Guide
| 
| 
| 
Technology
| Technology
3002018391
| 3002018391
Digital Systems Engineering: Test Strategies and Methods
| Digital Engineering
| Strategy
| I&C
| 
| 
Technology
| Technology
3002023869
| 3002023869
Roadmap Towards an Autonomous Plant: A High-Level Overview of Technologies Important for Autonomous Plant Operation
| Automation
| Atonomous
| Digital
| 
| 
Technology
| Technology
3002018392
| 3002018392
HFAM - Human Factors Analysis Methodology for Digital Systems: A Risk-Informed Approach to Human Factors Engineering
| Digital 
| I&C
| Human Factors
| Engineering
| 
People & Process
| People & Process
3002022944
| 3002022944
Common Design Package for Guided Wave Sensors and Monitoring System: Real-Time NDE: Plant Modernization
| Monitoring
| Sensors
| Design
| 
| 
Technology
| Technology
3002002953
| 3002002953
Principles and Approaches for Developing Overall Instrumentation and Control Architectures that Support Acceptance in Multiple International Regulatory Environments
| Digital
| I&C
| Architecture
| 
| 
Technology
| Technology
3002000537
| 3002000537
Methods and Tools for Evaluating Digital Control System Architectures
| Architecture
| I&C
| Digital controls
| 
| 
Technology
| Technology
3002015754
| 3002015754
SymPLe Architecture and Methodology: Achieving Verifiable and High Integrity Instrumentation and Control Systems Through Complexity Awareness and Constrained Design
| Architecture
| Digital
| Digital Controls
| 
| 
Technology
| Technology
3002018393
| 3002018393
SymPLe Architecture Phase II: Platform Evolution
| Architecture
| Digital
| Digital Controls
| 
| 
Technology
| Technology
3002015757
| 3002015757
Guidelines for Electromagnetic Compatibility Testing of Power Plant Equipment: Revision 5 to TR-102323
| EMC
| EMI
| I&C
| Guide
| 
Data
| Data
3002025693
| 3002025693
Program on Technology Innovation: Landscape of Automation in Nuclear Power Plants
| Automation
| Atonomous
| Monitoring
| 
| 
Technology
| Technology
3002003126
| 3002003126
Advanced Nuclear Technology: Data-Centric Configuration Management for Efficiency and Cost Reduction: An Economic Basis for Implementation
| Configuration Management
| data-centric
| 
| 
| 
Technology
| Technology
1024859
| 1024859
Human Factors Engineering (HFE) Computer Based Training Module for Utilities Involved in Implementing Digital Instrumentation and Control Systems
| Digital Controls
| CBT
| Human Factors
| 
| 
People & Process
| People & Process
3002023837
| 3002023837
Program on Technology Innovation: Creating a Digital Twin of a Radiological Environment
| Digital Twin
| sensor
| monitoring
| 
| 
Technology
| Technology
3002020427
| 3002020427
Integrating the EPRI TAM into a Digital Control System Conceptual Design: A Cyber Security Technical Assessment Methodology Topical Guide
| Cyber Security
| Digital I&C
| Technical assesment methodology
| 
| 
Security
| Security
3002023839
| 3002023839
EPRI Robotics Research: Electromagnetic Compatibility Assessment of SPOT Robotic Platform
| robotics
| EMI
| EMC
| Digital
| 
Technology
| Technology
3002015755
| 3002015755
Digital Systems Engineering: Configuration Management Guideline
| digital
| I&C
| configuration management
| guide
| 
Technology
| Technology
3002015758
| 3002015758
Digital Systems Engineering: Requirements Engineering Guideline
| digital
| engineering
| I&C
| guide
| 
Technology
| Technology
3002020429
| 3002020429
Digital Engineering Guide: Documentation Strategies Topical Guide
| guide
| configuration
| strategy
| engineering
| 
Technology
| Technology
3002023800
| 3002023800
Energy Supply Common Information Model (ES-CIM) Testbed v1.0
| common information model
| integration
| interoperability
| testbed
| 
Data
| Data
3002020923
| 3002020923
Application Integration Using Standards-Based Messaging: Implementation of Energy Supply Common Information Model (ES-CIM) Interfaces
| common information model
| integration
| interoperability
| cloud
| 
Data
| Data
3002022172
| 3002022172
Energy Supply Common Information Model GitHub Repository (ES-CIM) v1.0
| common information model
| integration
| interoperability
| 
| 
Data
| Data
3002020920
| 3002020920
Plant Modernization Application Integration Study: Overview of Integration Cost and Challenges in Enterprise Projects
| common information model
| integration
| interoperability
| digital worker
| 
Data
| Data
3002020913
| 3002020913
Unmanned Aircraft System (UAS) User's Guide for Nuclear Power Plants: Implementation Guidance, Technologies and Applications, and Cost Savings Opportunities
| drone
| UAS
| inspections
| guide
| 
Technology
| Technology
3002018430
| 3002018430
Plant Modernization Toolbox
| modernization
| business case
| guide
| strategy
| 
Strategy
| Strategy
3002019454
| 3002019454
Business Case Analysis Model (BCAM) v2.0
| business case
| nuclear
| modernization
| 
| 
Strategy
| Strategy
3002015795
| 3002015795
Cyber Security Division of Responsibility Topical Guide
| cyber security
| digital
| guide
| 
| 
Security
| Security
3002015761
| 3002015761
Cyber Security Data Flow Identification and Documentation Topical Guide
| Cyber Security
| Technical Assessment Methodology
| data flow
| 
| 
Security
| Security
3002016346
| 3002016346
Application of Remote Monitoring Technologies to Risk-Inform Condition Based Radiological Surveys
| sensor
| monitoring
| radiation
| nuclear
| 
Technology
| Technology
3002015794
| 3002015794
Cyber Security Baseline Configuration Topical Guide
| Cyber Security
| Technical Assessment Methodology
| configuration management
| 
| 
Security
| Security
3002015759
| 3002015759
Domain Controller Cyber Security Data Sheet (CSDS) Topical Guide
| Cyber Security
| Technical Assessment Methodology
| configuration
| 
| 
Security
| Security
3002016698
| 3002016698
HAZCADS: Hazards and Consequences Analysis for Digital Systems - Revision 1
| digtial
| hazcads
| I&C
| assessment
| 
Security
| Security
3002018387
| 3002018387
DRAM: Digital Reliability Analysis Methodology
| digital
| analysis
| reliablity
| 
| 
Security
| Security
3002021063
| 3002021063
PRE-SW: Concrete Defect Detection Tool (CDDT) v1.0 Beta
| machine learning
| API
| image analysis
| inspection
| 
Technology
| Technology
3002023977
| 3002023977
NextGen RP - Specifications for Autonomous Contamination Survey Robots: Functional Specifications Document
| robotics
| automation
| radiation
| nuclear
| 
Technology
| Technology
3002020977
| 3002020977
Next Generation Radiation Protection (NextGen RP): Assessment of Remote and Automated Technologies to Optimize Nuclear Power Plant Emergency Preparedness Programs
| automation
| sensor
| monitoring
| radiation
| nuclear
Technology
| Technology
3002023860
| 3002023860
Artificial Intelligence for Inventory Management: Demand Prediction Proof-of-Concept Model Evaluation
| AI
| inventory
| prediction
| 
| 
Technology
| Technology
3002025138
| 3002025138
Preventive Maintenance Basis Database (PMBD) v7.0
| sensor
| monitoring
| fault tree
| strategy
| guide
People & Process
| People & Process
3002024847
| 3002024847
Longterm Asset Management Basis Design Application (LAMBDA) v1.05
| application
| lifecycle
| 
| 
| 
People & Process
| People & Process
3002020837
| 3002020837
Determining Configurability and Consequences of Error of Digital Devices
| digital
| 
| 
| 
| 
Technology
| Technology
3002022397
| 3002022397
Cable Fault Location Field Guide - Mobile App
| digital worker
| Mobile Work Management
| guide
| fault
| 
Technology
| Technology
3002018286
| 3002018286
Electric Motor Microelectromechanical Systems (MEMS): Sensors for the Detection of Internal Stressors
| sensors
| motor
| 
| 
| 
Technology
| Technology
3002018279
| 3002018279
Digital Equivalency Evaluation: Screening Checklist and Considerations, Revision 1-An Updated Approach That Considers Item Configurability and Consequences of Error
| digital
| engineering
|  guide
| 
| 
Technology
| Technology
3002018281
| 3002018281
Wireless Technologies as a Replacement for Degraded Cable Systems
| Cyber Security
| wireless
| telecommunications
| monitoring
| sensor
Data
| Data
3002012784
| 3002012784
Developing a Technical Basis for Using On-Line Equipment Condition Monitoring to Reduce Time-Based Preventive and Predictive Maintenance
| sensor
| monitoring
| guide
| reliability
| 
People & Process
| People & Process
3002023921
| 3002023921
Enhanced Security and Reliability Using Artificial Intelligence
| AI
| monitoring
| cyber security
| 
| 
Security
| Security
3002023839
| 3002023839
EPRI Robotics Research: Electromagnetic Compatibility Assessment of SPOT Robotic Platform
| robotics
| EMI
| EMC
| digital
| telecommunications
Technology
| Technology
3002021179
| 3002021179
Incident Response Scenario Development Methodology: A Methodology for Developing Incident Response Scenarios for Operational Technology
| OT
| cyber security
| 
| 
| 
Security
| Security
3002023751
| 3002023751
Exploration of Drone Indoor Navigation Using Visual Markers: An Evaluation of the Design and Testing of a Visual Navigation System
| drone
| UAV
| UAS
| 
| 
Technology
| Technology
3002023739
| 3002023739
Installing Patches and Updates Using a Bounded Specification: A Cyber Security Topical Guide
| Cyber Security
| software
| patch
| digital
| guide
Security
| Security
3002023747
| 3002023747
Cyber Security Exercise Scenarios: Second Edition
| Cyber Security
| 
| 
| 
| 
Security
| Security
3002023841
| 3002023841
SymPLe Architecture Phase II: Refinement, Advancement, and Demonstration of SymPLe Architecture
| architecture
| I&C
| nuclear
| 
| 
Technology
| Technology
3002023549
| 3002023549
Integrated Security Research Summary Infographic: Enhanced Security and Reliability Using Artificial Intelligence
| AI
| cyber security
| monitoring
| 
| 
Security
| Security
3002020430
| 3002020430
A Study in Analyzing Published Cyber Security Vulnerabilities Using Natural Language Processing
| Cyber Security
| AI
| NLP
| 
| 
Security
| Security
3002018370
| 3002018370
Instrumentation and Control (I&C) Connector Operating Experience and Maintenance Guide
| I&C
| guide
| OT
| 
| 
Technology
| Technology
3002018374
| 3002018374
Identifying Relationship Sets Topical Guide
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Data
| Data
3002018375
| 3002018375
Security Information and Event Monitor (SIEM) Configuration for Closed Networks Topical Guide
| Cyber Security
| Technical Assessment Methodology
| guide
| Monitoring
| 
Security
| Security
3002015795
| 3002015795
Cyber Security Division of Responsibility Topical Guide
| Cyber Security
| guide
| procurment
| 
| 
Security
| Security
3002011817
| 3002011817
Safety Integrity Level (SIL) Certification Efficacy for Nuclear Power
| OT
| I&C
| safety integrity level
| 
| 
Technology
| Technology
3002015793
| 3002015793
Secure Development, Integration, and Delivery (SDID) Audit Topical Guide
| Cyber Security
| procurment
| guide
| 
| 
Security
| Security
3002012707
| 3002012707
Wireless Technology Assessment: Analysis of Radiated Emissions from Common Phones, Laptops, and Tablets
| EMC
| wireless
| digital worker
| EMI
| RFI
Data
| Data
3002012754
| 3002012754
Cyber Security Program Guide for Nuclear Power Facilities
| Cyber Security
| guide
| nuclear
| 
| 
Security
| Security
3002011818
| 3002011818
Wireless Sensor Survey and General Specification
| EMI
| EMC
| monitoring
| sensor
| wireless
Data
| Data
3002010577
| 3002010577
Online Monitoring Guide for Equipment Diagnostics and Reliability-Nuclear Generation
| sensor
| monitoring
| guide
| 
| 
Technology
| Technology
3002008018
| 3002008018
Systems Engineering Process: Methods and Tools for Digital Instrumentation and Control Projects
| I&C
| guide
| 
| 
| 
People & Process
| People & Process
3002006737
| 3002006737
Design Considerations for Replacing Single Loop Controllers and Other Controls with Field Programmable Gate Array-Based Equipment
| I&C
| OT
| controllers
| FPGA
| 
Technology
| Technology
3002008025
| 3002008025
Guidance for Instrumentation and Control Equipment Reliability Management Based on China General Nuclear Power Company Experience
| I&C
| guide
| 
| 
| 
Technology
| Technology
3002005369
| 3002005369
Technologies for Enhancing Verifiability of Embedded I&C Systems in Nuclear Power: A Survey of Advanced FPGA and MEMs Technologies
| I&C
| MEMs
| FPGA
| 
| 
Technology
| Technology
3002004995
| 3002004995
Program on Technology Innovation: Analysis of Hazard Models for Cyber Security, Phase I
| Cyber Security
| hazard
| 
| 
| 
Security
| Security
3002005367
| 3002005367
Program on Technology Innovation: Video Content Analytics for Nuclear Process Monitoring: A Technology Survey
| machine vision
| AI
| monitoring
| sensor
| 
Technology
| Technology
3002005324
| 3002005324
Reverse Engineering via Computer Simulation and Visualization of Nuclear Plant Printed Circuit Boards
| digital
| OT
| 
| 
| 
Technology
| Technology
3002003255
| 3002003255
Cyber Security Procurement Methodology, Application Pilots: Lessons Learned
| Cyber Security
| procurment
| 
| 
| 
Security
| Security
3002023930
| 3002023930
Quick Insight Brief: Using Artificial Intelligence to Maximize the Benefits of Drones for Nuclear Power Plants
| AI
| drones
| inspections
| 
| 
Data
| Data
3002023718
| 3002023718
AI-Assisted Analysis of Ultrasonic Inspections
| AI
| inspection
| UT
| AI-assisted
| 
Technology
| Technology
3002023821
| 3002023821
Automating Corrective Action Programs in the Nuclear Industry
| AI
| machine learning
| NLP
| automation
| CAP
People & Process
| People & Process
3002021061
| 3002021061
Data Mining to Support Integrated Monitoring and Diagnostics
| APR
| monitoring
| data mining
| machine learning
| 
Data
| Data
3002021048
| 3002021048
Machine Learning to Improve ID Pit Sizing in Balance-of-Plant (BOP) Heat Exchanger Tubes: Target-Type 304 Stainless Steel Tubing
| machine learning
| eddy current inspection
| inspections
| 
| 
Technology
| Technology
3002020931
| 3002020931
Use of Augmented Intelligence for Decommissioning Planning
| AI
| augmented intelligence
| 
| 
| 
People & Process
| People & Process
3002021055
| 3002021055
Automated Analog Gauge Reader: Benchmarking and Python Source Code
| image processing
| AI
| machine vision
| monitoring
| 
Technology
| Technology
3002020411
| 3002020411
Proof of Concept: Developing a Machine Learning Algorithm Trained with Synthetic Data that Can Identify Parallel Misalignment in Real Vibration Data
| monitoring
| machine learning
| vibration
| AI
| 
Technology
| Technology
3002021067
| 3002021067
Quick Insight Brief: Leveraging Artificial Intelligence for the Nuclear Energy Sector
| machine learning
| AI
| guide
| 
| 
Technology
| Technology
3002021074
| 3002021074
Quick Insight Brief: Leveraging Artificial Intelligence for Nondestructive Evaluation
| AI
| machine learning
| NDE
| inspection
| 
Technology
| Technology
3002020120
| 3002020120
Application of Data Analytics to Mine Nuclear Plant Maintenance Data
| AI
| machine learning
| analytics
| data
| 
Technology
| Technology
3002019731
| 3002019731
Using Machine Learning to Predict Flow-Accelerated Corrosion Wear Rates
| machine learning
| FAC
| AI
| 
| 
Technology
| Technology
3002018272
| 3002018272
Technical Avatar Proof of Concept Using IBM Watson
| AI
| NLP
| machine learning
| 
| 
Technology
| Technology
3002015801
| 3002015801
Program on Technology Innovation: Leveraging Data Science for Electric Power Industry Transformation
| data
| analytics
| data science
| 
| 
People & Process
| People & Process
3002013197
| 3002013197
Guidance for Implementing a Data Validation and Reconciliation Program at Nuclear Power Plants
| data validation
| reconciliation
| monitoring
| sensor
| 
Technology
| Technology
3002005345
| 3002005345
Program on Technology Innovation: Evaluation of Data Reconciliation Methods for Power Recovery
| data validation
| reconciliation
| monitoring
| sensor
| 
Technology
| Technology
3002013226
| 3002013226
Image Processing of Four-Face Fuel Assembly Visual Inspections: A Feasibility Study
| machine vision
| inspection
| 
| 
| 
Technology
| Technology
3002023905
| 3002023905
Program on Technology Innovation: Using Digital Engineering Tools and Methods for New Nuclear Projects--A Review of the State of the Art
| digital twin
| digital engineering
| common information model
| 
| 
Technology
| Technology
3002023899
| 3002023899
Robotic Process Automation for Nuclear Power Plants: Evaluation of Near-Term Opportunities
| robotics
| automation
| drones
| automous
| 
Technology
| Technology
3002022555
| 3002022555
Quick Insight Brief: Elements of Digital Twins and Projects Updates
| digital twin
| 
| 
| 
| 
Technology
| Technology
3002020014
| 3002020014
Quick Insight Brief: Digital Twin Activities at EPRI
| digital twin
| 
| 
| 
| 
Technology
| Technology
3002012752
| 3002012752
Cyber Security Technical Assessment Methodology: Risk Informed Exploit Sequence Identification and Mitigation, Revision 1
| Cyber Security
| hazard
| methodology
| 
| 
Security
| Security
3002013296
| 3002013296
Human Factors Engineering (HFE) Computer Based Training Module for Utilities Involved in Implementing Digital Instrumentation and Control Systems
| CBT
| I&C
| Human Factors
| 
| 
People & Process
| People & Process
3002010493
| 3002010493
Advanced Nuclear Technology: Assessment of Automation Technologies to Reduce Chemistry and Radiochemistry O&M Costs
| Automation
| sensor
| chemistry
| 
| 
Technology
| Technology
3002010470
| 3002010470
Advanced Nuclear Technology: Guidance for Cyber Security During New Nuclear Plant Construction
| Cyber Security
| procurment
| nuclear
| 
| 
Security
| Security
3002010467
| 3002010467
Advanced Nuclear Technology: Augmented Reality Technologies for New Nuclear Plant Applications
| augmented reality
| AR
| digital worker
| nuclear
| 
Technology
| Technology
3002008039
| 3002008039
Program on Technology Innovation: HTTPN, Securing Nuclear Network Communications in the Age of the Internet of Things
| Cyber Security
| HTTPN
| nuclear
| 
| 
Data
| Data
3002004310
| 3002004310
Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification
| I&C
| human factors
| guide
| 
| 
People & Process
| People & Process
3002005236
| 3002005236
Advanced Nuclear Technology: Guideline for Online Monitoring Requirements to Support TSTF-425 Instrumentation and Control Surveillance Management Programs
| I&C
| monitoring
| guide
| sensor
| 
Technology
| Technology
3002002852
| 3002002852
Advanced Nuclear Technology: Guidance and Methodologies for Managing Digital Instrumentation and Control Obsolescence
| I&C
| obsolescence
| guide
| 
| 
Technology
| Technology
3002002499
| 3002002499
Cyber Security Procurement Methodology Training Module Rev. 14.00
| CBT
| cyber security
| procurment
| 
| 
Security
| Security
3002002556
| 3002002556
Guidelines for Instrument Calibration Extension/Reduction - Revision 2: Statistical Analysis of Instrument Calibration Data
| I&C
| sensor
| analysis
| 
| 
People & Process
| People & Process
3002019845
| 3002019845
Plant Modernization Business Case: Improved Thermal Performance Through Data Validation and Reconciliation: Cost-Benefit Analysis of DVR Analysis for Power Recovery or Measurement Uncertainty Recapture Uprates
| business case
| I&C
| sensor
| 
| 
Strategy
| Strategy
3002020579
| 3002020579
Plant Modernization Business Case: Digital Safety-Related Instrumentation and Control (I&C) System Modernizations: Cost-Benefit Analysis of Implementing Digital Upgrades to Analog Safety-Related I&C Components to Reduce Operating and Material Purchase Co
| business case
| I&C
| sensor
| 
| 
Strategy
| Strategy
3002020884
| 3002020884
Nuclear Plant Modernization Business Case: Business Process Automation for Online Work Management
| business case
| AI
| machine learning
| Automation
| digital worker
Strategy
| Strategy
3002019843
| 3002019843
Plant Modernization Business Case: Electronic Work Packages (eWPs) for Maintenance Work: Cost-Benefit Analysis of Implementing eWPs to Reduce Operating Costs
| business case
| eWP
| data anlaytics
| digital worker
| 
Strategy
| Strategy
3002019844
| 3002019844
Plant Modernization Business Case-Improved Thermal Performance Through Cycle Isolation Monitoring: Cost-Benefit Analysis of Cycle Isolation Monitoring for Addressing Valve Repairs That Lead to Lost MWe
| business case
| sensor
| 
| 
| 
Strategy
| Strategy
3002018424
| 3002018424
Plant Modernization Business Case: Monitoring and Diagnostic (M&D) Program Development: Cost-Benefit Analysis of Implementing Online Monitoring (OLM) and an M&D Program to Reduce Operating Costs and Avoid Outage and Derate Costs
| business case
| monitoring
| sensor
| M&D
| 
Strategy
| Strategy
3002020885
| 3002020885
Plant Modernization Business Case: Monitoring and Diagnostics (M&D) Program Development Update
| business case
| monitoring
| sensor
| M&D
| 
Strategy
| Strategy
3002018480
| 3002018480
Plant Modernization Business Case: Monitoring Piping Subjected to Flow-Accelerated Corrosion
| business case
| sensor
| FAC
| 
| 
Strategy
| Strategy
3002021027
| 3002021027
Plant Modernization Business Case: Drone Inspections of Containment Structures
| business case
| drones
| inspections
| AI
| machine vision
Strategy
| Strategy
3002021026
| 3002021026
Plant Modernization Business Case: Sensors for Post-Tensioned Tendons
| business case
| sensor
| 
| 
| 
Strategy
| Strategy
3002020581
| 3002020581
Plant Modernization Business Case: Cost-Benefit Analysis for Implementation of the EPRI Virtual NDE (VNDE) Ultrasonic Simulator
| business case
| simulator
| virtual
| 
| 
Strategy
| Strategy
3002018481
| 3002018481
Plant Modernization Business Case: Monitoring Heat Exchanger Shells
| business case
| sensor
| 
| 
| 
Strategy
| Strategy
3002018483
| 3002018483
Plant Modernization Business Case: Monitoring Service Water Piping
| business case
| sensor
| 
| 
| 
Strategy
| Strategy
3002020974
| 3002020974
[NextGen%20RP%20Plant%20Modernization%20Business%20Case:%20Modernizing%20Nuclear%20Power%20Plant%20Emergency%20Response%20Field%20Monitoring%20Team%20Technologies NextGen RP Plant Modernization Business Case: Modernizing Nuclear Power Plant Emergency Response Field Monitoring Team Technologies]
| business case
| drones
| sensor
| 
| 
Strategy
| Strategy
3002020440
| 3002020440
Plant Modernization Business Case: Automated Chemistry
| business case
| sensor
| chemistry
| automation
| 
Strategy
| Strategy
3002023760
| 3002023760
Investigation of Oil Sensor Technology for Online Monitoring, Rev. 1
| monitoring
| sensor
| oil
| 
| 
Technology
| Technology
3002023765
| 3002023765
Electronic Work Package Platform Indicators and Pilot Project Findings
| eWP
| digital worker
| mobile
| 
| 
Technology
| Technology
3002021295
| 3002021295
Enterprise Asset Management Guide: Implementation and Utilization
| enterprise asset mangement
| CMMS
| 
| 
| 
People & Process
| People & Process
3002018209
| 3002018209
Terry Turbine Virtual Reality Application (TTVR), Version 1.0
| virtual reality
| VR
| 3D
| 
| 
Technology
| Technology
3002018210
| 3002018210
Circuit Breaker Virtual Reality Application (CBVR) Version 1.0
| virtual reality
| VR
| 3D
| 
| 
Technology
| Technology
3002017753
| 3002017753
Developing a Cyber Security Culture in the Operational Technology (OT) Environment
| OT
| cyber security
| CBT
| training
| 
Security
| Security
3002012785
| 3002012785
Continuous Online Monitoring Pilot Study: Quick Guide Pilots Show Real Savings
| monitoring
| sensor
| M&D
| 
| 
Technology
| Technology
3002012917
| 3002012917
Mobile Rigger's Handbook (MRHB), v1.0
| digital worker
| mobile
| 
| 
| 
Technology
| Technology
3002012915
| 3002012915
Configuration and Demonstration of 433-MHz Wireless Gauge Reader
| machine vision
| wireless
| 
| 
| 
Data
| Data
3002011674
| 3002011674
Demonstration of Smart Monitoring and Diagnostic Technologies for Electrical Equipment: Electromagnetic Signature Analysis and Motor Current Signature Analysis
| monitoring
| sensor
| M&D
| 
| 
Technology
| Technology
3002011132
| 3002011132
Work Order Data Visualization Tool Tutorial Video
| data visualization
| 
| 
| 
| 
People & Process
| People & Process
3002009546
| 3002009546
Work Order Data Visualization Tool
| data visualization
| 
| 
| 
| 
People & Process
| People & Process
3002010622
| 3002010622
Program on Technology Innovation: Evaluation of 433 MHz Sensors in Nuclear Power Plants
| wireless
| sensors
| telecommunications
| 
| 
Data
| Data
3002005521
| 3002005521
Program on Technology Innovation: Machine Verification in Laser-Scanned Spaces - Status Update 2
| machine vision
| augmented reality
| AR
| 
| 
Technology
| Technology
3002003062
| 3002003062
Program on Technology Innovation: Machine Verification in Laser-Scanned Spaces-Status Update 1
| machine vision
| augmented reality
| AR
| 
| 
Technology
| Technology
3002020971
| 3002020971
Neutron Monitoring at Nuclear Power Plants
| sensor
| radiation
| monitoring
| 
| 
Technology
| Technology
3002018409
| 3002018409
Autonomous Indoor Radiation Survey and Inspection Drone Demonstration at Peach Bottom
| automation
| drones
| UAV
| UAS
| radiation
Technology
| Technology
3002013946
| 3002013946
Program on Technology Innovation: Heat Stress Monitoring and Sensors-Phase 1, State of Science of Wearable Physiological Monitors to Assess Occupational Heat Strain
| sensor
| monitoring
| digital worker
| 
| 
Technology
| Technology
3002005480
| 3002005480
Remote Monitoring Technology Guide for Radiation Protection: Field Implementation of Remote Monitoring, 2015 Revision
| robotics
| radiation
| monitoring
| 
| 
Technology
| Technology
3002023964
| 3002023964
SMART Chemistry Quick Guide - Data Trending/Evaluation/Transfer
| data trending
| data transfer
| guide
| chemistry
| guide
Technology
| Technology
3002023121
| 3002023121
SMART Chemistry Quick Guide-Online Boron Analysis Quick Guide
| monitoring
| chemistry
| automation
| guide
| sensor
Technology
| Technology
3002020976
| 3002020976
SMART Chemistry Quick Guide-BWR Online Offgas Analysis
| monitoring
| chemistry
| automation
| guide
| sensor
Technology
| Technology
3002020441
| 3002020441
SMART Chemistry: Plant Demonstrations
| monitoring
| chemistry
| automation
| guide
| sensor
Technology
| Technology
3002017886
| 3002017886
Chemistry Monitoring and Assessment Database Web Application (CMA Web), version 4.0
| monitoring
| chemistry
| guide
| sensor
| 
Technology
| Technology
3002015805
| 3002015805
SMART Chemistry QUICK GUIDE - Steam Generator Blowdown Online Monitoring: Modular Approach
| monitoring
| diagnostics
| sensor
| chemistry
| guide
Technology
| Technology
3002014377
| 3002014377
SMART Chemistry Quick Guide: Online Ion Chromatograph
| monitoring
| chemistry
| guide
| sensor
| 
Technology
| Technology
3002010493
| 3002010493
Advanced Nuclear Technology: Assessment of Automation Technologies to Reduce Chemistry and Radiochemistry O&M Costs
| Automation
| chemistry
| monitoring
| sensor
| 
Technology
| Technology
3002024148
| 3002024148
Remote Proctoring Implementation in the Nuclear Power Industry: A Review of Remote Proctoring for Knowledge Assessments
| AI
| training
| remote
| 
| 
People & Process
| People & Process
3002025291
| 3002025291
Assisted Analysis for Remote Visual Examination Data: Version 1.0 Pre-Beta Project Technical Update Report and Software Manual
| AI
| NDE
| 
| 
| 
Technology
| Technology
3002023709
| 3002023709
Ultrasonic Monitoring Technologies for Flow Accelerated Corrosion: Reference Guide
| NDE
| monitoring
| UT
| sensor
| 
Technology
| Technology
3002023703
| 3002023703
Assessment of 3D Camera Technology for Visual Testing
| 3D
| camera
| NDE
| 
| 
Technology
| Technology
3002023458
| 3002023458
Realtime Augmented Reality for Nondestructive Examination Report
| UT
| NDE
| AR
| augmented reality
| 
Technology
| Technology
3002023457
| 3002023457
Realtime Augmented Reality for Nondestructive Examination Video
| UT
| NDE
| AR
| augmented reality
| 
Technology
| Technology
3002021049
| 3002021049
Advanced Ultrasonic Technologies for Balance-of-Plant (BOP) Applications
| UT
| NDE
| sensor
| FAC
| 
Technology
| Technology
3002021019
| 3002021019
Feasibility of Monitoring Ultrasonic Examination Indications Using Phased Array Ultrasonics from a Fixed Position: Laboratory Testing of Crack Growth Experiments at Ambient Temperature
| UT
| NDE
| monitoring
| sensor
| 
Technology
| Technology
3002021043
| 3002021043
Automated Analysis of Ultrasonic Inspection of Reactor Vessel Upper Head Penetration Welds
| UT
| NDE
| automation
| sensor
| 
Technology
| Technology
3002021017
| 3002021017
Guided Wave Monitoring of Heat Exchanger Shells: Real-Time NDE-Plant Modernization
| guided wave
| monitoring
| sensor
| automation
| NDE
Technology
| Technology
3002018463
| 3002018463
Capability Study on Hyperspectral Imaging and Deep Neural Networks for Classification of Chemical Deposits: Feasibility of Classification of Reactor Vessel Deposits
| machine learning
| AI
| NDE
| inspection
| 
Technology
| Technology
3002013193
| 3002013193
Remote Visual Inspections with Unmanned Aerial Systems
| drone
| UAS
| UAV
| inspection
| 
Technology
| Technology
3002010448
| 3002010448
State of Structural Health Monitoring Technologies for Nuclear Applications
| UT
| guided wave
| monitoring
| 
| 
Technology
| Technology
3002010567
| 3002010567
Nondestructive Evaluation: Guided Wave Inspection Technology for Pipes with Elbows: Improvements to Inspection Reliability and Efficiency
| NDE
| inspection
| sensor
| monitoring
| 
Technology
| Technology
3002013152
| 3002013152
Nondestructive Evaluation: Virtual Mockups-Electronic Implantation of Flaw Responses into Previously Recorded Data
| NDE
| training
| virtual
| inspection
| 
Technology
| Technology
3002020914
| 3002020914
Quick Insight Brief: Digitized Knowledge Sharing-Curating Information form NRC Adams Using Text Mining and Natural Language Processing-A Proof of Concept
| NLP
| AI
| nuclear
| 
| 
Data
| Data
3002020872
| 3002020872
Continuous On-Line Monitoring (COLM): Water Intake Screen
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002020869
| 3002020869
Electrical Signature Analysis (ESA) for On-Line Equipment Condition Monitoring: Fault Detection Testing
| sesnors
| monitoring
| 
| 
| 
Technology
| Technology
3002020874
| 3002020874
Continuous On-Line Monitoring (COLM): Horizontal Motor, Low Voltage-Squirrel Cage
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002020873
| 3002020873
Continuous On-Line Monitoring (COLM): Vertical Pump, Deep Draft-Axial Flow
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002020875
| 3002020875
Continuous On-Line Monitoring (COLM): Horizontal Motor, Low Voltage-Wound Rotor
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015791
| 3002015791
Continuous On-Line Monitoring: HVAC - Air Handling Equipment - Air Handling Equipment - Propeller Fans
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015790
| 3002015790
Continuous On-Line Monitoring: HVAC - Air Handling Equipment - Vane Axial Fans
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015789
| 3002015789
Continuous On-Line Monitoring: HVAC - Air Handling Equipment - Centrifugal Fans
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015788
| 3002015788
Continuous On-Line Monitoring: Large Fan - Induced Draft or Forced Draft - Centrifugal
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002015787
| 3002015787
Continuous On-Line Monitoring: Large Fan - Induced Draft or Forced Draft - Axial
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012767
| 3002012767
Continuous On-Line Monitoring: Main Condenser
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002016977
| 3002016977
Quick Guide: Continuous Online Monitoring (COLM)-Station MPT_GSU with De-Energized Tap Changer (DETC)
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012784
| 3002012784
Developing a Technical Basis for Using On-Line Equipment Condition Monitoring to Reduce Time-Based Preventive and Predictive Maintenance
| sensor
| monitoring
| 
| 
| 
Technology
| Technology
3002012781
| 3002012781
Continuous Online Monitoring (COLM): Vertical Motor, Medium Voltage <15KV - Solid Shaft - Rolling Element - Oil or Grease Lubricated
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012781
| 3002012781
Continuous Online Monitoring (COLM): Vertical Motor, Medium Voltage <15KV - Solid Shaft - Rolling Element - Oil or Grease Lubricated
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012780
| 3002012780
Continuous Online Monitoring (COLM): Horizontal Pump, Horizontal Pump - Multistage - Barrel Type
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012779
| 3002012779
Continuous Online Monitoring (COLM): Compressor, Rotary Screw - Oil Flooded and Oil Free
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012777
| 3002012777
Continuous Online Monitoring (COLM): Couplings, Elastomeric Type - Jaw or Spider Insert
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012776
| 3002012776
Continuous Online Monitoring (COLM): Couplings, Disc or Diaphragm Type
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012775
| 3002012775
Continuous Online Monitoring (COLM): Couplings, Gear Type - Grease Lubricated
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012774
| 3002012774
Continuous Online Monitoring (COLM): Heat Exchanger, General Tube Type
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012773
| 3002012773
Continuous Online Monitoring (COLM): Positive Displacement Pump
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012771
| 3002012771
Continuous Online Monitoring (COLM): Horizontal Motor, Medium Voltage <15kV - Horizontal - TEFC - Sleeve Bearing - Oil Lubed
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012770
| 3002012770
Continuous Online Monitoring (COLM): Horizontal Motor, Medium Voltage <15kV - Horizontal - TEFC - Rolling Element - Grease Lubed
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012769
| 3002012769
Continuous Online Monitoring (COLM): Horizontal Pumps, Horizontal - Single Stage - Single Suction
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012768
| 3002012768
Continuous Online Monitoring (COLM): Horizontal Pumps, Horizontal - Multistage - Split Case Pump
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002013864
| 3002013864
Continuous On-Line Monitoring (COLM): Horizontal Pumps, Horizontal - Single Stage - Double Suction
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002011820
| 3002011820
Online Monitoring - Engineering Change Package Content for a Distributed Antenna System and Wireless Vibration Sensors
| monitoring
| sensors
| telecommunications
| 
| 
Technology
| Technology
3002012766
| 3002012766
Continuous On-Line Monitoring (COLM): Horizontal Motors, Medium Voltage <15kV - Horizontal - Filters - Sleeve Bearing - Oil Lubed
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012765
| 3002012765
Continuous On-Line Monitoring (COLM): Medium Voltage Vertical Motors, Medium Voltage <15kV - Vertical - Solid Shaft - Tilt Pad - Sleeve Guide - Oil Lubed
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002012763
| 3002012763
Continuous On-Line Monitoring (COLM): Vertical Pump, Vertical - Deep Draft - Radial Flow - Product Lube
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
3002000742
| 3002000742
On-Line Monitoring of Emergency Diesel Generators
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1022988
| 1022988
Guideline for On-Line Monitoring of Nuclear Power Plant Instrument Channel Performance
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1021187
| 1021187
Status Report on On-Line Monitoring: Generation Step-Up Transformers
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1021116
| 1021116
Guideline for Initiating an Online Monitoring Program for Nuclear Power Plants
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1016725
| 1016725
Requirements for On-line Monitoring in Nuclear Power Plants
| COLM
| monitoring
| sensors
| 
| 
Technology
| Technology
1015173
| 1015173
Plant Application of On-Line Monitoring for Calibration Interval Extension of Safety-Related Instruments
| sensors
| monitoring
| 
| 
| 
People & Process
| People & Process
1013486
| 1013486
Plant Application of On-Line Monitoring for Calibration Interval Extension of Safety-Related Instruments: Volume 1 and 2
| sensors
| monitoring
| 
| 
| 
People & Process
| People & Process
3002011818
| 3002011818
Wireless Sensor Survey and General Specification
| telecommunications
| sensors
| 
| 
| 
Data
| Data
3002010569
| 3002010569
Development of Prototype Modular Wireless Triaxial Vibration Sensor: Pilot Phase
| telecommunications
| sensors
| 
| 
| 
Data
| Data
3002008026
| 3002008026
Development of Prototype Modular Wireless Triaxial Vibration Sensor: Phase 2
| telecommunications
| sensors
| 
| 
| 
Data
| Data
3002000502
| 3002000502
Preventive Maintenance Practices for Digital Instrumentation and Control Systems
| I&C
| sensors
| controls
| 
| 
Technology
| Technology
3002018394
| 3002018394
Electromagnetic Interference (EMI) Troubleshooting Guide
| EMI
| guide
| EMC
| 
| 
Data
| Data
3002000528
| 3002000528
Guidelines for Electromagnetic Compatibility Testing of Power Plant Equipment: Revision 4 to TR-102323
| EMC
| EMI
| guide
| 
| 
Data
| Data
3002001823
| 3002001823
Cyber Security Procurement - Application of the Methodology, Second Example: Feedpump Turbine Speed Control
| Cyber Security
| control
| I&C
| 
| 
Security
| Security
3002002069
| 3002002069
Cyber Security Procurement-Application of the Methodology, Third Example: Digital Feedwater Control
| Cyber Security
| control
| I&C
| 
| 
Security
| Security
3002003255
| 3002003255
Cyber Security Procurement Methodology, Application Pilots: Lessons Learned
| Cyber Security
| 
| 
| 
| 
Security
| Security
3002020426
| 3002020426
Developing a Regulatory Requirements and Compliance Map: A Cyber Security Technical Assessment Methodology Topical Guide
| Cyber Security
| guide
| Technical assesment methodology
| 
| 
Security
| Security
3002017149
| 3002017149
SEL 487E Protective Relay Reference Cyber Security Data Sheet (CSDS): Cyber Security Technical Assessment Methodology Use Case Study
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Security
| Security
3002015737
| 3002015737
Exploit Sequence Identification and Mitigation (EXSIM) v1.0
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Security
| Security
3002015760
| 3002015760
Risk Informed Target Level Topical Guide
| Cyber Security
| Technical Assessment Methodology
| 
| 
| 
Security
| Security
3002012753
| 3002012753
Cyber Security in the Supply Chain: Cyber Security Procurement Methodology, Revision 2
| Cyber Security
| procurment
| 
| 
| 
Security
| Security
3002012239
| 3002012239
Elemental Fault Signature Information for Select Power Plant Assets
| monitoring
| sensors
| 
| 
| 
Technology
| Technology
3002000755
| 3002000755
On-Line Monitoring Diagnostic Analysis for Emergency Diesel Generators
| COLM
| sensors
| monitoring
| 
| 
Technology
| Technology
3002000753
| 3002000753
On-Line Monitoring Diagnostic Analysis for Large Power Transformers
| COLM
| sensors
| monitoring
| 
| 
Technology
| Technology
3002015880
| 3002015880
Area-Wide Acoustic and Electromagnetic (AEM) Signature Health Monitoring: Phase 2
| monitoring
| sensors
| 
| 
| 
Technology
| Technology
3002023747
| 3002023747
Cyber Security Exercise Scenarios: Second Edition
| Cyber Security
| 
| 
| 
| 
Security
| Security

PDU

Product ID Reports
! Keyword 1
! Keyword 2
! Keyword 3
! Keyword 4
! Keyword 5
Strategic Focus Area
3002023752
| 3002023752
Digital Transformation Framework: Utility Strategy and Implementation Guide
| framework
| strategy
| guide
| 
| 
Strategy
| Strategy
3002024188
| 3002024188
Common Information Model Primer: Eighth Edition
| integration
| common information model
| CIM
| standards
| 
Data
| Data
3002024186
| 3002024186
Cloud Integration Guidebook, 7th Edition: A Guide for Enterprise Architects
| cloud
| architecture
| system
| integration
| 
Strategy
| Strategy
3002024191
| 3002024191
Architectural Impacts of Disruptive Technology
| enterprise architecture
| business capabilities
| roadmap
| 
| 
Strategy
| Strategy
3002024190
| 3002024190
Information Technology-Operational Technology Convergence Guidebook: Fifth Edition
| enterprise architecture
| IT
| OT
| 
| 
Strategy
| Strategy
3002024183
| 3002024183
Utility Enterprise Architecture Guidebook, 7th Edition
| enterprise architecture
| integration
| system
| architecture
| 
Strategy
| Strategy
3002025527
| 3002025527
Diagramming OT Cyber Security Threats, Vulnerabilities, and Impacts
| security
| archimate
| OT
| 
| 
Security
| Security
3002021349
| 3002021349
Exploring a Data Centric Approach for Digital Utilities
| enterprise architecture
| integration
| data
| strategy
| 
Strategy
| Strategy
3002021853
| 3002021853
A Framework for Relating the Elements of Strategy Development through Implementation
| enterprise architecture
| roadmap
| capability
| model
| 
Strategy
| Strategy
3002025136
| 3002025136
Utility Business Capability Guidebook
| enterprise architecture
| roadmap
| capability
| model
| 
Strategy
| Strategy
3002021938
| 3002021938
White Paper: Business Capability: Motivations and Meta-Models
| enterprise architecture
| roadmap
| capability
| model
| 
Strategy
| Strategy
3002021853
| 3002021853
A Framework for Relating the Elements of Strategy Development through Implementation
| enterprise architecture
| roadmap
| capability
| model
| 
Strategy
| Strategy
3002023081
| 3002023081
Business Capability Model: Capability Progressions and Maturity
| enterprise architecture
| roadmap
| capability
| model
| roadmap
Strategy
| Strategy
3002024929
| 3002024929
EPRI Utility Business Capability Model
| enterprise architecture
| roadmap
| capability
| model
| 
Strategy
| Strategy
No PID
| No PID
EPRI Utility Business Capability Model - Public Version
| 
| 
| 
| 
| 
Strategy
| Strategy
3002017677
| 3002017677
Program on Technology Innovation: Toward a Utility Digital Transformation Maturity Model
| enterprise architecture
| OT
| IT
| strategy
| 
Strategy
| Strategy
3002026252
| 3002026252
Global Innovation Effectiveness Project - 2022 Update
| innovation
| assessment
| 
| 
| 
Strategy
| Strategy
3002023411
| 3002023411
Global Innovation Effectiveness Assessment
| innovation
| assessment
| 
| 
| 
Strategy
| Strategy
3002020923
| 3002020923
Application Integration Using Standards-Based Messaging
| CIM
| common information model
| integration
| standards
| 
Data
| Data
3002009981
| 3002009981
Point-to-Point Standards Integration Cost Framework
| integration
| data
| standards
| 
| 
Data
| Data
3002020920
| 3002020920
Overview of Integration Cost and Challenges in Enterprise Projects
| integration
| common information model
| stategy
| 
| 
Data
| Data
3002002586
| 3002002586
Common Information Model Framework for Asset Health Data Exchange
| CIM
| common information model
| integration
| standards
| 
Data
| Data

Generation

Product ID Reports
! Keyword 1
! Keyword 2
! Keyword 3
! Keyword 4
! Keyword 5
! Keyword 6
Strategy Focus Area
3002025746
| 3002025746
A Primer on Data Analytics in Digital Transformation
| Data analytics
| Predictive analytics
| Digital platform
| Prescriptive analytics
| Data-driven decision making
|  
Strategy
| Strategy
3002024586
| 3002024586
A Primer on the Role of Process Control and Automation in Digital Transformation: EPRI Digital Transformation Primer Series
| Process Control
| Automation
| Digital transformation
| Centralized control
|  
|  
People & Process
| People & Process
3002024653
| 3002024653
Operationalization of Data for Analytics
| Operations
| Data Integration
| Analytics
| Data architecture
| Data models
| Digital transformation
Data
| Data
3002023316
| 3002023316
Hydropower Digital Twin Roadmap Development
| Monitoring
| Hydropower
| Diagnostics
| Roadmap
| Digital twin
|  
Technology
| Technology
3002024417
| 3002024417
Digital Demonstration Facility: Digital Twin Update
| Gas turbine
| F-class gas turbines
| Digital twin (DT)
|  
|  
|  
Technology
| Technology
3002024540
| 3002024540
Health Index for Balance of Plant Equipment: Phase I Progress Update
| Condition Based Maintenance
| Equipment Health
| Health index
| Data analytic tools
|  
|  
Technology
| Technology
3002025266
| 3002025266
A Discussion on Automated Diagnostics
| Monitoring
| Automated diagnostics
| Data-driven fault signatures
| Knowledge-based fault signatures
|  
|  
Technology
| Technology
3002024444
| 3002024444
Industrial Advanced Data Analytics Readiness Assessment Primer
| Optimization
| Automation
| Machine learning
| Artificial intelligence (AI)
| Advanced data analytics
| Data driven decision making
Data
| Data
3002023790
| 3002023790
Thermal Fatigue Model for Wind Turbine Generator Life Prediction: Physics-based Model for Real Time Health Monitoring
| Reliability
| Insulation systems
| Wind Turbine
| Generator
| Miner's rule
| Physics based thermal model
Technology
| Technology
3002023921
| 3002023921
Enhanced Security and Reliability Using Artificial Intelligence
| Security
| Cybersecurity
| Integrated security operations center (ISOC)
| Artificial intelligence (AI)
| Monitoring and diagnostic (M&D)
|  
Security
| Security
3002024337
| 3002024337
Securing Wireless Communications in Power Generation Environments: A Process for Evaluating and Securing Wireless Deployments
| Wireless sensors
| Power generation
| Cyber Security
| Internet of Things (IoT)
| Industrial Internet of Things (IIoT)
| Operational technology (OT)
Data
| Data
3002013664
| 3002013664
I4Gen Intelligent Generation: Fundamentals of a Digital and Analytics Platform for Data Integration, Analysis, and Actionable Information
| Analytics
| System architecture
| Big Data
| Predictive analytics
| 14Gen
| Predictve maintenance
Technology
| Technology
3002011541
| 3002011541
Interactive Remote Access Guidance: Generation Cyber Security
| Cyber Security
| Cybersecurity
| Remote access
| Hardware-based cybersecurity
| Interactive remote access
|  
Security
| Security
3002011542
| 3002011542
Connected Component Reference Architectures: Securing Connected Components in Power Generation-Interactive Remote Access, Vendor Use Case
| Information Technology
| Cyber Security
| Integration
| Enterprise Architecture
| Interactive remote access
|  
Data
| Data
3002024348
| 3002024348
Controls Job Card Digitization Framework: Wireframe Layout Overview
| Flexible operations
| Digitization
| Thermal power systems
|  
|  
|  
Technology
| Technology
3002024507
| 3002024507
New Applications of Remote Sensing Technologies in Aquatic Habitat Assessments: Summary of Findings
| Remote Sensing
| Drones
| sonar
| Artificial intelligence (AI)
|  
|  
Technology
| Technology
3002024049
| 3002024049
Drone Applications for LP Steam Turbines: Interactive Guide
| Steam turbine
| Visual inspection
| Remote Inspection
| Drone
| UAS
| Last Stage Blade
Technology
| Technology
3002024159
| 3002024159
A Critical Assessment of Boiler Chemistry Action Level Limits Using Electrochemical Techniques and Computerized Tomography
| Boiler water chemistry
| X-ray computed tomography
| All-volatile treatment
| Chloride contamination
| Localized corrosion rates
| Oxide layer growth
Technology
| Technology
3002024097
| 3002024097
Generator Rotor Ground Faults-Online Detection
| Online Monitoring
| Generator rotor
| Ground faults
| Generator rotor damage
|  
|  
Technology
| Technology
3002024723
| 3002024723
Work Management Guidelines for Power Plant Personnel: Long-Range Plans, Outages, Preventive Maintenance, Core Maintenance Schedules, and Daily Schedule Interactions Explained
| Scheduling
| Outage
| Work planning
| On-line maintenance
| Work management
|  
People & Process
| People & Process
3002024227
| 3002024227
High-Level Flexibility Assessment and Benchmarking Tool: Combined-Cycle Units
| Combined Cycle
| Operational flexibility
| Benchmarking
| Assessments
|  
|  
Technology
| Technology
3002024325
| 3002024325
Application of In-Situ Optical Continuous Emission Monitoring Systems under Current Regulatory Framework: Gas Turbine Combined Cycle Case Study
| UV-DOAS
| Gas turbine combined cycle (GTCC)
| Continuous emissions monitoring (CEM)
| Laser based monitors
| Multi-specie monitors
|  
Technology
| Technology
3002016451
| 3002016451
Wind Turbine Performance Monitoring Methods Development and Demonstration: Digitalization of Wind Assets to Increase Production Revenue
| Operations and Maintenance (O&M)
| Digitalization
| Power curves
| Wind Turbine Performance Monitoring
|  
|  
Technology
| Technology
3002016434
| 3002016434
Wind Turbine Gearbox Reliability, Damage Prediction, and Recommendations for Life Improvement: Digitalization of Wind Assets to Reduce O&M Costs
| Bearings
| Gears
| Health monitoring
| Gearbox
| Digitalization
| Drivetrain
Technology
| Technology
3002022015
| 3002022015
Summary of Insight Through the Integration of Information for Intelligent Generation (I4Gen): 2021 Update
| Sensors
| Data analytics
| Digital transformation
| Return on investment
|  
|  
Data
| Data
3002022113
| 3002022113
Introduction to Data Integration for Power Generation
| Data Integration
| Data architecture
| Data platform
|  
|  
|  
Data
| Data
3002022197
| 3002022197
Digital Twin Self Calibration Tool: Guideline for Gas Turbines v1.0
| Gas turbine
| Digital twin
| Historian data
| Model calibration
| Multi-unit calibration
|  
Technology
| Technology
1017638
| 1017638
Best Practices for the Application of Hand-Held Computers to Operator Rounds
| Operator rounds
| Electronic data collection
| Handheld computers
|  
|  
|  
People & Process
| People & Process
3002020549
| 3002020549
Digital Twin: A Primer on Digital Twins with a Focus on Gas Turbines
| Gas Turbines
| Digital twin
| Artificial intelligence (AI)
| Machine learning (ML)
| Computer-based modeling
|  
Technology
| Technology
3002024417
| 3002024417
Digital Demonstration Facility: Digital Twin Update
| Gas turbine
| F-class gas turbines
| Digital twin (DT)
|  
|  
|  
Technology
| Technology
3002018048
| 3002018048
I4Gen Intelligent Generation: Digital Platform Roadmap
| Data analytics
| System architecture
| Predictive analytics
| Digital transformation
| Digital platform
|  
Strategy
| Strategy
3002020702
| 3002020702
Advanced Thermal Performance Monitoring Methods
| Performance Evaluation
| Heat Rate
| Thermal Efficiency
| Diagnostic models
| Thermal performance monitoring
| Heat balance models
Technology
| Technology
3002014276
| 3002014276
Mobile Deployment Technology for Fossil Stations: Member Case Studies, 2018
| Cost-benefit analysis
| Financial modeling
| Mobile work management
| Return on investment (ROI)
|  
|  
Technology
| Technology
3002023752
| 3002023752
Digital Transformation Framework: Utility Strategy and Implementation Guide
| Innovation
| Modernization
| Digital transformation
| Strategy framework
|  
|  
Strategy
| Strategy
3002013664
| 3002013664
I4Gen Intelligent Generation: Fundamentals of a Digital and Analytics Platform for Data Integration, Analysis, and Actionable Information
| Analytics
| System architecture
| Big Data
| Predictive analytics
| 14Gen
| Predictve maintenance
Data
| Data
3002011560
| 3002011560
EPRI I4Gen Evaluation of Predictive Analytics Techniques
| Predictive Maintenance
| Neural Networks
| Artificial Intelligence
| Predictive analytics
| I4Gen
| Machine learning
Data
| Data
3002013663
| 3002013663
I4GEN Intelligent Generation White Paper: Maturity Levels for Key Application Areas Within EPRI's Intelligent Plant Concept
| Automation
| Digital Systems
| Data analytics
| Process controls
| Advanced monitoring
| Intelligent generation
Strategy
| Strategy
3002015109
| 3002015109
I4Gen Project 1: Data Visualization: EPRI v16.0
| Data visualization
| Dashboard
| Data-driven decisions
| Team collaboration
|  
|  
Data
| Data
3002018040
| 3002018040
Remaining Useful Life Approaches for Rotating Equipment Case Study and Implementation Evaluation
| Rotating Machinery
| Condition-Based Maintenance
| Prognostics and Health Management
| Remaining useful life
|  
|  
Technology
| Technology
3002019837
| 3002019837
Equipment Health Dashboard Optimization
| Reliability
| Data visualization
| Equipment health dashboard
|  
|  
|  
Data
| Data
3002016871
| 3002016871
Digital Worker and Data Collection: A Proof of Concept
| Sensors
| Data Compilation
| Worker Safety
| Power generation
| Digital technology
| Digital worker
Technology
| Technology
3002023360
| 3002023360
Securing Digital Worker Technologies: Operational Technology(OT)/Information Technology (IT) Framework for Evaluating Cyber Security when Deploying Digital Worker Technology
| Information Technology
| Cyber Security
| Information technology/operations technology (IT/OT) convergence
| Operational technology (OT)
| Digital worker technology
| IT/OT integration
Security
| Security
3002020296
| 3002020296
Tag Whisperer (TW) v1.0
| Standardization
| AI
| NLP
|  
|  
|  
Data
| Data
3002021062
| 3002021062
Application of Novel Random Forest Approach for Environmental Controls: Development Status
| Electrostatic Precipitators
| Emission Control
| Random forest
| Machine learning
| Artificial intelligence (AI)
|  
Data
| Data
3002020233
| 3002020233
Improving Large-Scale PV Plant Monitoring and Diagnostics: Irradiance Sensor Benefit-Cost Analysis and Accuracy Assessment
| Performance
| Monitoring and diagnostics
| Sensor
| Photovoltaic
| Irradiance
| Pyranometer
Technology
| Technology
3002021732
| 3002021732
Evaluating Photovoltaic (PV) Plant Health: Best Practices for Comparing Actual Performance Versus Expected
| Performance
| Photovoltaics
| Solar
| Health
| Regression
| Empirical
Technology
| Technology
3002025605
| 3002025605
Wind Network for Enhanced Reliability (WinNER) v2.0
| Reliability
| Bearings
| Gears
| Wind Turbine
| Rotor
| Blade
Data
| Data
3002023104
| 3002023104
ReFLEx Calculator: Impact of Site and Operating Conditions on Wind Turbine Life Infographic
| Wind Turbines
| Budgeting
| O&M
| Components
| Operating conditions
| Life expectancy
Technology
| Technology
3002022663
| 3002022663
I4GEN(r) Insight Through the Integration of Information for Intelligent Generation
| Monitoring and diagnostics
| Digital technology
| Success story
| Generating assets
| Intelligent generation
| Plant modernization
Strategy
| Strategy
3002003913
| 3002003913
Predictive Maintenance Technologies: An Overview of Motor Current Signature Analysis and Electromagnetic Signature Analysis Enterprise Asset Management Guide: Implementation and Utilization
| Anomaly detection
| Predictive maintenance
| Electromagnetic signature analysis (EMSA)
| Motor currant signature analyis (MCSA)
|  
|  
Technology
| Technology
3002015411
| 3002015411
Remaining Useful Life Approaches for Rotating Equipment
| Rotating Machinery
| Condition-Based Maintenance
| Prognostics and Health Management
| Remaining useful life
|  
|  
Technology
| Technology
3002016342
| 3002016342
Nondestructive Evaluation (NDE) Mapping Technology Research for Feedwater Heater Shell Flow-Accelerated Corrosion (FAC)
| Nondestructive evaluation (NDE)
| Flow-accelerated corrosion (FAC)
| Ultrasonic testing (UT)
| Feedwater chemistry
| Feedwater heater (FWH) shell
| Pulse eddy current (PEC)
Technology
| Technology
3002011933
| 3002011933
Use of Asset Fault Signatures in Conjunction with Advanced Pattern Recognition Software
| Advanced pattern recognition
| APR
| AFS
| Asset fault signatures
| Fault diagnostics
|  
Technology
| Technology
3002021295
| 3002021295
Enterprise Asset Management Guide: Implementation and Utilization
| Asset management
| Work management
| Computerized maintenance management system (CMMS)
| Enterprise asset management (EAM)
|  
|  
People & Process
| People & Process
3002006661
| 3002006661
Integrating Bulk Power Generation Assets into the Common Information Model
| Semantic model
| Unified Modeling Language (UML)
| Common information model (CIM)
| Data Model
| Generation standards
|  
Data
| Data
3002011218
| 3002011218
Guide to Develop Asset Fault Signature Using Fleetwide Prognostic and Health Management Suite Software
| Plant Health Monitoring Users Group
| Asset fault signature (AFS)
| Diagnostic advisor (DA)
|  
|  
|  
Technology
| Technology
3002015404
| 3002015404
Maintenance Case Study: Equipment Reliability Data Platform Specification-Proposed Connection of Korea Western Power Co.'s Maintenance Management System to EPRI Applications
| Preventive Maintenance
| Equipment Reliability
| Data analytics
|  
|  
|  
Technology
| Technology

TI

Product ID Reports
! Keyword 1
! Keyword 2
! Keyword 3
! Keyword 4
! Keyword 5
Strategic Focus Area
3002023924
| 3002023924
Artificial Intelligence for Energy Storage Operation: Energy Arbitrage
| AI
| artificial intellegence
| 
| 
| 
Data
| Data
3002023869
| 3002023869
Roadmap Towards an Autonomous Plant: A High-Level Overview of Technologies Important for Autonomous Plant Operation
| automation
| roadmap
| 
| 
| 
Technology
| Technology
3002025395
| 3002025395
Secure Open-Source Data Acquisition Unit: A Raspberry Pi Proof-of-Concept
| DAQ
| 
| 
| 
| 
Data
| Data
3002024640
| 3002024640
A Scalable Control Architecture for 100% PV Penetration with Grid Forming Inverters - 2022 Update
| Architecture
| 
| 
| 
| 
Data
| Data
3002025630
| 3002025630
Applications of Robotics in Distribution Systems
| robotics
| distribution
| 
| 
| 
Technology
| Technology
3002024195
| 3002024195
Program on Technology Innovation: DER Gateway Reference Architecture
| Architecture
| DER
| gateway
| 
| 
Strategy
| Strategy
3002025693
| 3002025693
Program on Technology Innovation: Landscape of Automation in Nuclear Power Plants
| automation
| roadmap
| AI
| 
| 
Technology
| Technology
3002024196
| 3002024196
Simplifying and Streamlining Interoperability of Distributed Energy Resources: Application-Specific Profiles for DER Information and Protocol Standards
| integration
| standards
| information
| 
| 
Data
| Data
3002024880
| 3002024880
Applying Advanced Data Science Techniques to Better Understand Transmission and Distribution (T&D) Asset Performance
| analytics
| data science
| 
| 
| 
Data
| Data
3002023839
| 3002023839
EPRI Robotics Research: Electromagnetic Compatibility Assessment of SPOT Robotic Platform
| robotics
| EMI
| EMC
| 
| 
Data
| Data
3002024798
| 3002024798
Enhancing GIS Data Quality Using Artificial Intelligence Tools
| AI
| quaility 
| data
| 
| 
Data
| Data
3002023862
| 3002023862
Using Mobile Robotic Platform for Hazardous Tasks
| robotics
| 
| 
| 
| 
Technology
| Technology
3002025527
| 3002025527
Program on Technology Innovation: Diagramming OT Cyber Security Threats, Vulnerabilities, and Impacts
| security
| OT
| 
| 
| 
Security
| Security
3002025383
| 3002025383
Program on Technology Innovation: A Functional Application Architecture for Grid Model Data Management (GMDM)
| Architecture
| data management
| 
| 
| 
Data
| Data
3002023904
| 3002023904
Program on Technology Innovation: Digital Twin Applications for Advanced Reactors
| digital twin
| 
| 
| 
| 
Technology
| Technology
3002025428
| 3002025428
A Functional Application Architecture for Grid Model Data Management: Model Files
| Architecture
| data management
| 
| 
| 
Data
| Data
3002023841
| 3002023841
SymPLe Architecture Phase II: Refinement, Advancement, and Demonstration of SymPLe Architecture
| Architecture
| 
| 
| 
| 
Technology
| Technology
3002023837
| 3002023837
Program on Technology Innovation: Creating a Digital Twin of a Radiological Environment
| digital twin
| radiation
| 
| 
| 
Technology
| Technology
3002023905
| 3002023905
Program on Technology Innovation: Using Digital Engineering Tools and Methods for New Nuclear Projects--A Review of the State of the Art
| digital engineering
| 
| 
| 
| 
People & Process
| People & Process
3002023899
| 3002023899
Robotic Process Automation for Nuclear Power Plants: Evaluation of Near-Term Opportunities
| automation
| AI
| 
| 
| 
Technology
| Technology
3002022348
| 3002022348
Program on Technology Innovation: Hardware-Based Reference Signatures-An Approach to Digital Hardware Verification
| signature
| 
| 
| 
| 
Security
| Security
3002023458
| 3002023458
Realtime Augmented Reality for Nondestructive Examination Report
| AR
| augmented
| reality
| NDE
| 
Technology
| Technology
3002023018
| 3002023018
Incubatenergy Labs 2021 Pilot Project Report - Copper Labs: Wireless Real-Time Energy Monitoring for Demand Management and Grid-Edge Intelligence
| monitoring
| 
| 
| 
| 
Technology
| Technology
3002023022
| 3002023022
Incubatenergy Labs 2021 Pilot Project Report - DCSix Technologies: Circuit-Level Monitoring and Analytics for a Multifamily Residential Community
| monitoring
| analytics
| 
| 
| 
Technology
| Technology
3002023030
| 3002023030
Incubatenergy Labs 2021 Pilot Project Report - LiveEO: Satellite-Based Post-Storm Disaster Monitoring and Damage Assessment
| monitoring
| 
| 
| 
| 
Technology
| Technology
3002023014
| 3002023014
Incubatenergy Labs 2021 Pilot Project Report - Buzz Solutions: PowerAI Platform for Automated Visual Inspection of Grid Infrastructure
| inspection
| AI
| 
| 
| 
Technology
| Technology
3002023033
| 3002023033
Incubatenergy Labs 2021 Pilot Project Report - Noteworthy AI: Automated Drive-By Distribution Asset Inspection
| inspection
| automation
| 
| 
| 
Technology
| Technology
3002023034
| 3002023034
Incubatenergy Labs 2021 Pilot Project Report - Pano AI - 360-Degree, AI-Based Imaging for Wildfire Situational and Locational Awareness
| AI
| 
| 
| 
| 
Technology
| Technology
3002023035
| 3002023035
Incubatenergy Labs 2021 Pilot Project Report - Shifted Energy: Machine-Learning-Based Load Shaping for Residential Water Heating
| AI
| ML
| 
| 
| 
Technology
| Technology
3002023023
| 3002023023
Incubatenergy Labs 2021 Pilot Project Report - Design Interactive: Instructor-Led, Live-Streamed Augmented Reality Training for Remote Workers
| AR
| augmented
| digital worker
| 
| 
Technology
| Technology
3002023025
| 3002023025
Incubatenergy Labs 2021 Pilot Project Report - Enerbrain: Intelligent Monitoring and Control for Commercial Space Conditioning
| monitoring
| 
| 
| 
| 
Technology
| Technology
3002023027
| 3002023027
Incubatenergy Labs 2021 Pilot Project Report - Future Grid: Using Smart Meter Data for Distribution Network Visualization and Management
| network
| visualization
| smart meter
| 
| 
Technology
| Technology
3002023426
| 3002023426
Smart Grid Interoperability Standards Adoption in Southeast Asia
| integration
| standards
| 
| 
| 
Data
| Data
3002023511
| 3002023511
Utility Blockchain Interest Group: Energy Blockchain Update, Winter 2022
| blockchain
| data
| security
| DLT
| 
Security
| Security
3002022716
| 3002022716
Preparing for the 2030 Energy System: A Vision for Electric Utility Information and Communication Technologies (ICT) and the Role that EPRI's ICT Program Plays in Helping Members Realize This Vision
| communications
| data
| 
| 
| 
Data
| Data
3002022002
| 3002022002
Program on Technology Innovation: Artificial Intelligence Applications to Satellite Imagery - A Wildfire Risk Use Case Focused on Identification of Dead and Stressed Trees
| AI
| 
| 
| 
| 
Technology
| Technology
3002023460
| 3002023460
Hydropower Digital Twin: Roadmap
| digital twin
| hydro
| 
| 
| 
Technology
| Technology
3002023493
| 3002023493
Distributed Ledger Technology and the Internet of Things
| blockchain
| DLT
| Iot
| 
| 
Security
| Security
3002023316
| 3002023316
Hydropower Digital Twin Roadmap Development
| digital twin
| hydro
| 
| 
| 
Technology
| Technology
3002023218
| 3002023218
Field Communicating AR/VR Technology Enablers
| AR
| VR
| 
| 
| 
Technology
| Technology
3002022294
| 3002022294
Building the Digital Thread for Distribution
| digital
| 
| 
| 
| 
Technology
| Technology
3002021414
| 3002021414
Program on Technology Innovation: Utilizing AMI Data for Fault Anticipation
| fault
| data
| 
| 
| 
Technology
| Technology
3002023072
| 3002023072
Heatmap Visualization Tool Demonstration with Plug-In End-Use Loads
| visualization
| 
| 
| 
| 
Data
| Data
3002021563
| 3002021563
Exploration of machine learning applications for extracting network topologies from single-line drawings
| ML
| AI
| 
| 
| 
Technology
| Technology
3002021405
| 3002021405
Program on Technology Innovation: AI Based Dynamic Security Vulnerability Assessment: Power Distribution Systems with High DER Penetration
| Vulnerability
| 
| 
| 
| 
Security
| Security
3002023219
| 3002023219
5G Architecture - Evolution and Roadmap for the Utility Industry
| communications
| wireless
| 5G
| 
| 
Data
| Data
3002021407
| 3002021407
AI Based Vulnerability Assessment for Power Distribution Systems Considering Distributed Energy Resources (DERs)
| AI
| 
| 
| 
| 
Security
| Security
3002019514
| 3002019514
Assessing Grid Modernization Maturity
| maturity
| 
| 
| 
| 
Strategy
| Strategy
3002023194
| 3002023194
Stress Tree Detection using Hyperspectral and Multispectral Imagery Collected from Unmanned Aerial Vehicles
| drones
| aerial
| 
| 
| 
Technology
| Technology
3002021933
| 3002021933
Exploring the Potential for a Building Energy-Focused Data Hackathon
| hackathon
| 
| 
| 
| 
Data
| Data
3002019013
| 3002019013
Program on Technology Innovation: Enhanced DER Monitoring
| monitoring
| DER
| 
| 
| 
Technology
| Technology
3002021525
| 3002021525
Program on Technology Innovation: Environmental Data Science Use Cases - Quick Summaries and Select Deep Dives
| data science
| analytics
| 
| 
| 
Technology
| Technology
3002021418
| 3002021418
Documentation for the A-Diakoptics framework in OpenDSS and test cases
| dss
| a-diakoptics
| 
| 
| 
Technology
| Technology
3002023077
| 3002023077
A Reference Architecture for the Control Center of the Future: Model Files
| Architecture
| control
| 
| 
| 
Technology
| Technology
3002021852
| 3002021852
Program on Technology Innovation: A Reference Architecture for the Control Center of the Future
| Architecture
| control
| 
| 
| 
Technology
| Technology
3002021043
| 3002021043
Automated Analysis of Ultrasonic Inspection of Reactor Vessel Upper Head Penetration Welds
| automation
| NDE
| 
| 
| 
Technology
| Technology
3002022770
| 3002022770
Program on Technology Innovation: Using Hyperspectral Imagery and Artificial Intelligence (AI) to Detect Stressed and Dead Trees
| AI
| 
| 
| 
| 
Technology
| Technology
3002021854
| 3002021854
Advanced Metering Infrastructure (AMI) Reference Architecture
| Architecture
| 
| 
| 
| 
Strategy
| Strategy
3002022715
| 3002022715
Cyber Security Vision for 2030
| security
| 
| 
| 
| 
Security
| Security
3002016698
| 3002016698
HAZCADS: Hazards and Consequences Analysis for Digital Systems - Revision 1
| security
| HAZCADS
| 
| 
| 
Security
| Security
3002021526
| 3002021526
Sustainability Priorities for the North American Electric Power Industry: Assessment of Emerging Artificial Intelligence-Enabled Approaches
| AI
| 
| 
| 
| 
Technology
| Technology
3002022169
| 3002022169
Utility Blockchain Interest Group: Energy Blockchain Update, May 2021
| blockchain
| DLT
| 
| 
| 
Security
| Security
3002019701
| 3002019701
Program on Technology Innovation: Integrated Security Operations Center and Monitoring and Diagnostics Digital Data Integration for Advanced Cyber-Physical Detection Capability-A Roadmap for the Energy Sector
| monitoring
| diagnostics
| integrations
| 
| 
Security
| Security
3002020681
| 3002020681
Utilization of Emerging Data Science Technologies to Electric Power Sector Environmental Challenges: Index of Research
| data science
| analytics
| 
| 
| 
Technology
| Technology
3002020120
| 3002020120
Application of Data Analytics to Mine Nuclear Plant Maintenance Data
| mine
| 
| 
| 
| 
Data
| Data
3002020794
| 3002020794
Preparing for the 2030 Energy System: Why We Need a New Cyber Security Vision
| security
| 
| 
| 
| 
Security
| Security
3002020657
| 3002020657
Incubatenergy Labs 2020 Pilot Project Report: PingThings - PredictiveGrid Time-Series Data Platform
| predictive
| 
| 
| 
| 
Technology
| Technology
3002019867
| 3002019867
Program on Technology Innovation: In-Plant Common Information Model for eXtended Reality, Human Machine Interface
| integration
| standards
| common
| 
| 
Data
| Data
3002020324
| 3002020324
Potential Applications for Artificial Intelligence and Machine Learning in Coal Combustion Product Research: Methods and Applications
| AI
| 
| 
| 
| 
Technology
| Technology
3002019731
| 3002019731
Using Machine Learning to Predict Flow-Accelerated Corrosion Wear Rates
| ML
| AI
| FAC
| 
| 
Technology
| Technology
3002020292
| 3002020292
Digital Twins - A Promising Technology for Data-Centric Cyber Security
| digital twin
| 
| 
| 
| 
Technology
| Technology
3002020263
| 3002020263
Fuels for Small Unmanned Aircraft Systems (sUAS)
| drones
| aerial
| 
| 
| 
Technology
| Technology
3002019416
| 3002019416
Technology Innovation: Grid Cybersecurity for Automated Demand Response Ready Buildings
| security
| 
| 
| 
| 
Security
| Security
3002016561
| 3002016561
Data Analytics and Smart Cities
| analytics
| 
| 
| 
| 
Data
| Data
3002020222
| 3002020222
Metrics Hub: A Data Aggregation Platform for Security Metrics
| security
| 
| 
| 
| 
Security
| Security
3002019801
| 3002019801
Utility Cloud Cyber Security Working Group: 2020 Year-End Summary
| cloud
| security
| 
| 
| 
Security
| Security
3002018720
| 3002018720
A Scalable Control Architecture for 100% PV Penetration with Grid Forming Inverters
| Architecture
| 
| 
| 
| 
Strategy
| Strategy
3002019319
| 3002019319
Understanding Low-impact BES Cyber System NERC CIP Requirements for Cloud
| security
| CIP
| 
| 
| 
Security
| Security
3002019865
| 3002019865
Program on Technology Innovation: In-Plant Common Information Model (CIM) for eXtended Reality Applications
| CIM
| integration
| standards
| 
| 
Data
| Data
3002019887
| 3002019887
Real-Time Online Deposition Monitor for Heat Exchangers and Condensers
| monitoring
| 
| 
| 
| 
Technology
| Technology
3002018898
| 3002018898
Maximizing the Value of Right-of-Way (ROW) Unmanned Aircraft Systems (UAS) Collected Data: Four Applications for Remotely Sensed Data
| drones
| aerial
| 
| 
| 
Technology
| Technology
3002020058
| 3002020058
Program on Technology Innovation: Advantages of Digital Worker Technology in a Pandemic Scenario-An Overview of How Technology Can Reduce Touch Points and Aid in Social Distancing
| digital worker
| 
| 
| 
| 
Technology
| Technology
3002016584
| 3002016584
Program on Technology Innovation: Text Mining Endangered Species Act Permitting Documents Using Artificial Intelligence
| AI
| mining
| 
| 
| 
Data
| Data
3002019868
| 3002019868
Program on Technology Innovation: In-Plant Common Information Model for eXtended Reality, Communications Video
| CIM
| integration
| standards
| 
| 
Data
| Data
3002019968
| 3002019968
Program on Technology Innovation: Identifying Barriers and Solutions to Adoption of Data Tech for Environmental Issues
| data science
| 
| 
| 
| 
Data
| Data
3002019866
| 3002019866
Program on Technology Innovation: In-Plant Common Information Model for eXtended Reality, Messaging Infrastructure Video
| CIM
| integration
| standards
| 
| 
Data
| Data
3002018641
| 3002018641
Program on Technology Innovation: Web Services Robustness, An Agile Data Integration Ecosystem
| agile
| data
| integrations
| 
| 
Data
| Data
3002018740
| 3002018740
Program on Technology Innovation: Development of Deep Learning Methods to Classify Plankton from Holographic Images
| AI
| image
| 
| 
| 
Data
| Data
3002019774
| 3002019774
Algorithm Development for Shared Benefit of Behind-the-Meter Storage Assets
| data science
| 
| 
| 
| 
Data
| Data
3002018632
| 3002018632
Program on Technology Innovation: Software Containers in Utility Field Area Network
| software
| 
| 
| 
| 
Data
| Data
3002013420
| 3002013420
Program on Technology Innovation: Emerging and Data-Driven Solutions for Power Plant Control -- Interim Report
| controls
| 
| 
| 
| 
Technology
| Technology
3002016590
| 3002016590
Vegetation Management using Satellite Imaging, Augmented Reality, Artificial Intelligence, and Image Analysis
| AR
| AI
| image
| 
| 
Technology
| Technology
3002018224
| 3002018224
Program on Technology Innovation: Telecommunication Support for Extended Reality Wearables in the Field - An Introduction to 5G and WiFi 6 Wireless Field Communication Solutions for Extended Reality Wearables
| 5G 
| communications
| wireless
| 
| 
Data
| Data
3002019583
| 3002019583
Zero Trust Considerations for Utility OT Cyber Security Strategies
| OT
| security
| 
| 
| 
Security
| Security
3002019371
| 3002019371
The Digital Voice of Today's Utility Worker: An Instrument of Untapped Potential in T&D Operations and Maintenance
| digital worker
| 
| 
| 
| 
Technology
| Technology
3002016605
| 3002016605
Program on Technology Innovation: Optimizing Real-Time Spatiotemporal Sensor Placement for Monitoring Air Pollutants for Human Health Risk Assessment
| monitoring
| 
| 
| 
| 
Technology
| Technology
3002016599
| 3002016599
Program on Technology Innovation: New Frontiers in Milkweed Detection - Evaluating the Potential of Satellite Data and Machine Learning
| Data
| ML
| AI
| 
| 
Technology
| Technology
3002016327
| 3002016327
Program on Technology Innovation: Techniques for Detecting Faults in Multiple Induction Machines Using Only Aggregate Current Measurements-Phase 2: Plant Feasibility Study
| fault
| monitoring
| 
| 
| 
Technology
| Technology
3002017669
| 3002017669
Case Studies of Integrated Energy Network Planning Challenges - Volume 2: Phase 2 - Framework for Integrated Energy Network Planning (IEN-P)
| integration
| network
| 
| 
| 
Data
| Data
3002017577
| 3002017577
Technology Innovation Program: Secure Cloud Reference Architecture for Real-Time Utility-Based Applications
| Architecture
| cloud
| 
| 
| 
Data
| Data
3002017414
| 3002017414
Utilization of Emerging Data Science Technologies to Electric Power Sector Environmental, Health, and Safety Risks: Annotated Bibliography from a Literature Review
| Technology
| 
| 
| 
| 
Technology
| Technology
3002015813
| 3002015813
Program on Technology Innovation: Development of Adaptive Feedback Welding Technology for Fabrication and Repair Applications
| welding
| feedback
| 
| 
| 
Technology
| Technology
3002016043
| 3002016043
Program on Technology Innovation: Common Information Model (CIM) Power System Model Integration Using SOAP/REST
| CIM
| integration
| standards
| 
| 
Data
| Data
3002017438
| 3002017438
Machine Learning Applications for Improved Planning and Operation of the Power Grid
| ML
| 
| 
| 
| 
Technology
| Technology
3002015801
| 3002015801
Program on Technology Innovation: Leveraging Data Science for Electric Power Industry Transformation
| data science
| 
| 
| 
| 
Data
| Data
3002016583
| 3002016583
Utilization of Emerging Data Science Technologies to Address Electric Power Sector Environmental, Health, and Safety Risks: Early Insights from Interviews
| data science
| 
| 
| 
| 
Data
| Data
3002016558
| 3002016558
Program on Technology Innovation: Assessment of Safety Aspects of Using Augmented Reality Technologies - Field Tests with Electric Utility Power Plant Operators and Manhole Workers
| AR
| 
| 
| 
| 
Technology
| Technology
3002017148
| 3002017148
Program on Technology Innovation: Virtual Power Plant 3D Model User Dashboard
| 3D
| visualization
| 
| 
| 
Technology
| Technology
3002016955
| 3002016955
Program on Technology Innovation: Painting Robot - Functional Specification Development
| robotics
| 
| 
| 
| 
Technology
| Technology
3002016578
| 3002016578
Program on Technology Innovation: Potential for Augmented Reality in Groundwater Applications: Uses and Technology Survey
| AR
| visualization
| 
| 
| 
Technology
| Technology
3002016273
| 3002016273
Remote Vibrational Imaging Through Unmanned Aerial Vehicle (UAV) Integration
| drones
| aerial
| 
| 
| 
Technology
| Technology
3002015657
| 3002015657
Program on Technology Innovation: Managing Cloud Storage and BES Cyber System Information
| BES
| security
| 
| 
| 
Security
| Security
3002015063
| 3002015063
Unmanned Aircraft Systems (UAS): Advanced Payloads
| drones
| aerial
| 
| 
| 
Technology
| Technology
3002014985
| 3002014985
Hardware Security for Interactive Remote Access and Information Transfer: Phase 2b Production Prototype
| remote
| security
| 
| 
| 
Security
| Security
3002014700
| 3002014700
Program on Technology Innovation: Digital Worker Innovation Hub-An Initiative to Promote Digital Worker Research Across the Electric Power Research Institute
| digital worker
| 
| 
| 
| 
Technology
| Technology
3002012708
| 3002012708
Area-Wide Acoustic and Electromagnetic Emissions Monitoring
| monitoring
| 
| 
| 
| 
Technology
| Technology
3002014678
| 3002014678
Program on Technology Innovation: Evaluating IoT Messaging Protocols for DER Management
| DER
| standards
| messaging
| 
| 
Data
| Data
3002012752
| 3002012752
Cyber Security Technical Assessment Methodology: Risk Informed Exploit Sequence Identification and Mitigation, Revision 1
| security
| 
| 
| 
| 
Security
| Security
3002014615
| 3002014615
Evaluation and Development of Narrowband Internet of Things for Private Utility Networks: Scoping Study
| narrowband
| communications
| 
| 
| 
Data
| Data
3002014648
| 3002014648
Program on Technology Innovation: CIM-Based Power System Model Transport
| CIM
| integration
| standards
| 
| 
Data
| Data
3002014370
| 3002014370
Program on Technology Innovation: Understanding Internet of Things Architectures
| Architecture
| 
| 
| 
| 
Strategy
| Strategy
3002011586
| 3002011586
Program on Technology Innovation: Augmented Reality in Generation
| AR
| 
| 
| 
| 
Technology
| Technology
3002012753
| 3002012753
Cyber Security in the Supply Chain: Cyber Security Procurement Methodology, Revision 2
| security
| 
| 
| 
| 
Security
| Security
3002012915
| 3002012915
Configuration and Demonstration of 433-MHz Wireless Gauge Reader
| wireless
| monitoring
| 
| 
| 
Technology
| Technology
3002013946
| 3002013946
Program on Technology Innovation: Heat Stress Monitoring and Sensors-Phase 1, State of Science of Wearable Physiological Monitors to Assess Occupational Heat Strain
| monitoring
| 
| 
| 
| 
Technology
| Technology
3002014288
| 3002014288
Program on Technology Innovation: Annotated Bibliography for 10 Integrated Energy Network Planning Challenges, Phase 2 - Framework for Integrated Energy Network Planning (IEN-P)
| network
| integration
| 
| 
| 
Strategy
| Strategy
3002014308
| 3002014308
Overview of Reality Computing for Research in Energy and Space Exploration
| computing
| 
| 
| 
| 
Technology
| Technology
3002010821
| 3002010821
Developing a Framework for Integrated Energy Network Planning (IEN-P)
| integration
| guide
| 
| 
| 
Strategy
| Strategy
3002012532
| 3002012532
Program on Technology Innovation: Augmented Reality- Literature Review of Human Factors Issues in the Electric Power Industry
| human factors
| 
| 
| 
| 
People & Process
| People & Process
3002012297
| 3002012297
Program on Technology Innovation: A Decentralized Infrastructure for Monitoring and Control of Power Systems
| monitoring
| control
| 
| 
| 
Technology
| Technology
3002011621
| 3002011621
Hardware Security for Interactive Remote Access and Information Transfer: Phase 2a-Proof of Concept
| remote
| security
| 
| 
| 
Security
| Security
3002010237
| 3002010237
Summary of Interoperability Tracking and Reporting by the Information and Communication Technology Program in 2017
| communications
| integration
| 
| 
| 
Data
| Data
3002010242
| 3002010242
Blockchain: Technology Risk and Rewards for Utilities
| blockchain
| DLT
| 
| 
| 
Security
| Security
3002005810
| 3002005810
Program on Technology Innovation: Low-Cost Sensors for Electric End-Use Metering: State of the Market, Requirements and Applications
| monitoring
| 
| 
| 
| 
Technology
| Technology
3002010514
| 3002010514
Program on Technology Innovation: Enterprise Augmented Reality Vision, Interoperability Requirements, and Standards Landscape
| AR
| integration
| 
| 
| 
Data
| Data
3002010622
| 3002010622
Program on Technology Innovation: Evaluation of 433 MHz Sensors in Nuclear Power Plants
| sensing
| monitoring
| 
| 
| 
Technology
| Technology
3002009453
| 3002009453
Program on Technology Innovation: Citizen Science Species Data--An Introduction, Review of Current Uses, and Potential Benefits and Risks
| data science
| 
| 
| 
| 
People & Process
| People & Process
3002009416
| 3002009416
Program on Technology Innovation: An Evaluation of Radio Frequency Fields Produced by School WiFi Systems
| wireless
| communications
| 
| 
| 
Data
| Data
3002008125
| 3002008125
Hardware Security for Interactive Remote Access and Information Transfer - Phase 1: Design
| security
| remote
| 
| 
| 
Security
| Security
3002008039
| 3002008039
Program on Technology Innovation: HTTPN, Securing Nuclear Network Communications in the Age of the Internet of Things
| communications
| standards
| 
| 
| 
data
| data
3002009258
| 3002009258
Program on Technology Innovation: State of the Art of Wearable Enterprise Augmented Reality Displays
| AR
| digital worker
| 
| 
| 
Technology
| Technology
3002009240
| 3002009240
Program on Technology Innovation: Common Needed Attributes of an Architecture for an Integrated Grid
| Architecture
| integration
| 
| 
| 
data
| data
3002008860
| 3002008860
Program on Technology Innovation: Wearable Computers Assessment
| digital worker
| 
| 
| 
| 
Technology
| Technology
3002006955
| 3002006955
Program on Technology Innovation: Data Science Emergence and Relevance to EPRI Research and Member Utilities
| data
| science
| 
| 
| 
Data
| Data
3002007436
| 3002007436
Program on Technology Innovation: Autonomous Mobile Measurement Platform (AMMP)
| automation
| 
| 
| 
| 
Technology
| Technology
3002007428
| 3002007428
Program on Technology Innovation: Open Enabling Platform for Enterprise-Wide Interoperability and the Integrated Grid Year One Update: Connecting the Present to the Future
| integration
| standards
| 
| 
| 
Data
| Data
3002004995
| 3002004995
Program on Technology Innovation: Analysis of Hazard Models for Cyber Security, Phase I
| security
| 
| 
| 
| 
Security
| Security
3002005367
| 3002005367
Program on Technology Innovation: Video Content Analytics for Nuclear Process Monitoring: A Technology Survey
| analytics
| 
| 
| 
| 
Data
| Data
3002005521
| 3002005521
Program on Technology Innovation: Machine Verification in Laser-Scanned Spaces - Status Update 2
| scanning
| 
| 
| 
| 
Technology
| Technology
3002005345
| 3002005345
Program on Technology Innovation: Evaluation of Data Reconciliation Methods for Power Recovery
| DVR
| 
| 
| 
| 
People & Process
| People & Process
3002003545
| 3002003545
Program on Technology Innovation: Data Analytics and Customer Insights
| analytics
| 
| 
| 
| 
Technology
| Technology
3002003062
| 3002003062
Program on Technology Innovation: Machine Verification in Laser-Scanned Spaces-Status Update 1
| laser
| 
| 
| 
| 
Technology
| Technology